IDENTEC SOLUTIONS i-B2 S/NA Скачать руководство пользователя страница 3

 
i-B2 S – User’s Guide

 

 
Version 1.0 

03.08.2006 

Page iii/12 

 

 

 

 

Radio Frequency Compliance Statement 

 
IDENTEC SOLUTIONS AG. is the responsible party for the compliance of the following devices: 
 

MODEL: 

i-B2 S 

i-CARD CF 

i-D TAGS 

i-Qxx TAGS 

FCC ID: 

OO4-ILR-IB2NA 

OO4-ILR-ICARDCF 

OO4-ILR-ID2 

OO4-ILR-IQ8T or 
OO4-ILR-IQR 

CANADA: 

Pending 

Pending 

3538A 12112 

35381021756A or  
35381021825 

EUROPE: 

CE 

CE 

CE 0678(!) 

CE 0682(!) 

 
The user(s) of these products are cautioned to only use accessories and peripherals approved, in advance, by 
IDENTEC SOLUTIONS.  The use of accessories and peripherals, other than those approved by IDENTEC 
SOLUTIONS, or unauthorized changes to approved products, may void the compliance of these products and 
may result in the loss of the user(s) authority to operate the equipment. 
 
Operation is subject to the following conditions: (1) these devices may not cause harmful interference, and (2) 
these devices must accept any interference, including interference that may cause undesired operation of the 
device. 

 

FCC Compliance (i-B2 S/NA) 
 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference 
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate 
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause 
harmful interference to radio communication. Operation of this equipment in a residential area is likely to cause 
harmful interference in which case the user will be required to correct the interference at his/her own expense. 

Warning: Changes or modifications to this unit not expressly approved by the party responsible for 
compliance could void the user’s authority to operate the equipment. 

 

Industry Canada Compliance (i-B2 S/NA) 

 

This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment 
Regulations. 
 
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du 
Canada. 
 
To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the 
equivalent isotropically radiated power (EIRP) is not more than that required for successful communication. 
 
The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not 
emit RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable 
from Health Canada. 
 
 
 
 

Содержание i-B2 S/NA

Страница 1: ...i B2 S NA User s Guide Version 1 0 IDENTEC SOLUTIONS AG Millennium Park 2 A 6890 Lustenau Austria Tel 43 0 5577 87387 0 Fax 43 0 5577 87387 15 info identecsolutions at www identecsolutions com ...

Страница 2: ...ness IDENTEC SOLUTIONS AG shall not in any circumstances be liable to any person for any special incidental indirect or consequential damages including without limitation damages resulting from use of or reliance on information presented herein or loss of profits or revenues or costs of replacement goods even if informed in advance of the possibility of such damages Trademarks IDENTEC SOLUTIONS In...

Страница 3: ...vide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communication Operation of this equipment in a residential area is likely to cause harmful interference ...

Страница 4: ...mplies to Art 6 4 of R TTE Directive 1999 5 EC and can be used in the following European countries Austria Belgium Denmark Finland France Germany Greece Iceland Italy Ireland Luxembourg Netherlands Norway Portugal Switzerland Sweden Spain United Kingdom Czech Republic Cyprus Estonia Hungary Lithuania Latvia Malta Poland Slovenia ...

Страница 5: ...____________________________________________ 6 Appendix A Technical Specifications ____________________________7 Appendix B Battery lifetime__________________________________8 Appendix C Tag mounting___________________________________9 C 1 Rivets ______________________________________________9 C 2 Screws ____________________________________________10 C 3 Taping on metal surfaces __________________...

Страница 6: ...ts LSB first Can not be set or altered by the user User data Length 9 bytes Is reported by the reader in exactly the same format as programmed on the tag Can be written to the tag via a proximity 13 56 MHz link using IDENTEC SOLUTIONS i B2 programmer Flag byte Length 8 bits Meaning of the single bits depend on implemented tag functionality in the standard version these 8 bits are user definable Ag...

Страница 7: ...ry life See table Data Programmability One time Programming and activation Wireless by proximity device over a distance of maximum 5 cm Reprogrammable Yes Deactivation Yes Lockable Yes Memory capacity 4 bytes ID 9 bytes user data Environmental Operating temperature 30 C to 70 C 22ºF to 158ºF 1 50 C to 85 C 58 F to 185 F 1 Shock 50 G 3 times DIN IEC 68 2 27 Multiple drops to concrete from 1 m 3 ft ...

Страница 8: ...ily on ping rate and battery capacity The i B2 S can be equipped with either a 560 mAh or a 2 100 mAh battery Following table shows these influences Battery 560 mAh Battery 2 100 mAh Ping rate sec Lifetime years Max Age Counter Lifetime years Max Age Counter 0 5 1 25 74 4 90 147 1 0 2 43 73 9 56 144 2 0 4 65 69 10 137 5 0 10 00 61 10 120 10 0 10 51 10 100 ...

Страница 9: ...cess the rivet socket If there is a chance this might occur it is better to use a blind rivet with a large head1 or insert an M5 washer This has the effect of distributing the pressure over a larger surface area during riveting The use of the washer has the added effect of positioning the rivet slightly higher in the depression so that one can better access the rivet socket with the rivet gun 4 Me...

Страница 10: ... non rusting material 4 A temperature of at least 10 C 50 F must be maintained during mounting to prevent the casing from cracking 5 Depending on the type and strength category of the M5 screw used the maximum tightening torque must be between 2 and 10 Nm If the torque is any greater the screw may overtighten or the casing might break 6 Metal surfaces in direct proximity to the tag can reduce the ...

Страница 11: ...ocedure Preparation of surfaces Plastic casing preliminary cleaning 3M Primer 26 GZH 2 minutes waiting period Metal surface preliminary cleaning 3M Primer 86 A 15 minutes waiting period First attach tape to tag bottom and press on with the roll Then attach the tag to the prepared metal surface Important Information 1 Before using the tape cleaning agents and primers as listed need to check if thes...

Страница 12: ...Suction Cups Supplier i e Vakuplastic Kunststoff GmbH Co KG Berlin Vendor part number 1 1 3510 Suction cup 35mm 1 3 8 inch with threaded bolts M4 x 10 Glass plate clean free of fatty substances M4 washer M4 screw nut M4 screw nut 10 mm 0 4 inch bushing with M4 inside thread ...

Отзывы: