IDEMIA DOCUMENT
– REPRODUCTION AND DISCLOSURE PROHIBITED
Power supply
14
External Power Supply:
12-24 V (regulated and filtered) 3A min @12V, IEC60950-1 or IEC 62368-1 standard
compliant. If sharing power between devices, each unit must receive 3A (e.g. two units would require a 12
VDC, 6A supply).
St
ep
tw
o
:
w
iring
A battery backup or uninterrupted power supply (UPS) with built-in surge protection is recommended.
WARNING: Under powering may cause memory and data corruption; over powering may cause hardware damage.
Both of these situations will void the warranty
Gauge
AWG
Section
(mm
2
)
Maximum distance (meters) vs
power source rating
12 V
+/-
10%
3,6 A
12 V
+/-
5%
3,5 A
24 V +/-
10%
2 A
24 V +/-
10%
3 A
16
1.31
6 m
12 m
68 m
121 m
18
0.82
4 m
8 m
43 m
76 m
20
0.52
2 m
5 m
27 m
48 m
22
0.32
1 m
3 m
16 m
30 m
IDEMIA recommends using a 24V 3A power supply and
AWG16 gauge cable. The voltage measured on the product
block connector of the terminal must be equal to 12V-24V (-
15% / +10%).
The product requires 36 W at all voltage conditions.
The voltage drop due to the cable shall be taken into account.
The table at the right, shows the maximum distance between
power supply and 1 unique device, depending on cable gauge
and power supply rating.
IDEMIA - 2019_2000045730
– V1
1-3
Power + 12V
Red
2-4
Power GND
Black