Section 3 : Installation Procedure
2015_2000009096 V6
January 2019
IDEMIA
D
OCUMENT
–
R
EPRODUCTION AND
D
ISCLOSURE
F
ORBIDDEN
47
Output Relay
Figure 18: Output relay wiring (Initial version)
D
1
Relay 1
Contact relay (normally open)
2
Relay 2
Contact relay strip
Figure 19: Output relay wiring (Revision 2)
5
Yellow / White
Relay NO
Contact relay (normally open)
6
Grey / White
Relay COM
Contact relay common
7
Orange / White
Relay NC
Contact relay (normally closed)
Nominal characteristics of relay
Load characteristics:
2 A max @ 30 VDC (according to the safety extra low voltage requirements
independently of the power supply),
Resistive load or inductive load; see warning information hereafter for inductive
load.
Inductive load management requires a parallel diode for a better contact
lifetime.
1
6
1
6
1
6
1
6
A
B
C
D