Sensors
SA1J : Full Color Recognition
Connection Diagram (1-color version)
Wiring (1-color version)
Connection Example (1-color version)
Lead Wire Color
Name
Function
Brown
+V
Power voltage 12 to 24V
Blue
0V
Power ground
Pink
SET
Set input
Violet
EXT
External synchronous input
Black
OUT
Control output
Lead Wire
Brown
Blue
Pink
Violet
Black
I/O Circuit Example (SA1J-C1N1, -C2N1)
+ V (Brown)
OV
(Blue)
SET (Pink)
EXT (Violet)
OUT
(Black)
Main Circuit
Load
12 to 24V DC
I/O Circuit Example (SA1J-C1P1, -C2P1)
+ V (Brown)
OV (Blue)
SET
(Pink)
EXT (Violet)
OUT
(Black)
Main Circuit
Load
12 to 24V DC
Connection Diagram (3-color version)
Wiring (3-color version)
Connection Example (3-color version)
Lead Wire Color
Name
Function
Brown
+V
Power voltage 12 to 24V
Blue
0V
Power ground
Pink
SET
Set input
Violet
EXT
External synchronous input
Black
OUT A
Control output A
White
OUT B
Control output B
Gray
OUT C
Control output C
Lead Wire
Brown
Blue
Pink
Violet
Black
Gray
White
+ V (Brown)
SET (Pink)
EXT (Violet)
OUT (Black) (A)
Main
Circuit
12 to 24V DC
OUT (White) (B)
OUT (Gray) (C)
Load
Load
Load
(SA1J-C1N3, -C2N3)
(SA1J-C1P3, -C2P3)
+ V (Brown)
OV (Blue)
SET (Pink)
EXT (Violet)
OUT (Black) (A)
Main
Circuit
12 to 24V DC
OUT (White) (B)
OUT (Gray) (C)
Load
Load
Load
Use a non-contact output sensor for external synchronous input to prevent chattering.
Wiring, continued
Dimensions
2.59" (65.7mm)
0.69"
2-ø 0.21" (5.4mm)
3.15" (80mm)
2.68" (68mm)
2-M5 (Depth:10)
D1
1.65" (42mm)
1.97" (50mm)
(22mm)
0.87"
ø 0.21" (5.4mm)
0.28"
(7mm)
D1 = SA1J-C1
❏❏
model = ø 0.99" (25.2mm)
[SA1J-C2
❏❏
model = ø 1.06" (27mm)]
D2 = SA1J-C1
❏❏
model = ø 0.26" (7mm)
[SA1J-C2
❏❏
model = ø 0.50" (12.8mm)]
(17.6mm)
D2
1.18" (30mm)
TREICHL-ATM Electronic Auf der Bült 10 - 12 D 41189 Mönchengladbach
Tel. 02166 958545 Fax 02166 958547