Installation Requirements

Install the sensor so that distance “a” between the lens and

the object complies with the values shown in the table above.

Tilt the optical axis by approximately 15˚ to the vertical direc-

tion of the object surface.

Position the spot center away from the mounting hole. Refer

to the horizontal distance represented by “c.”

Determine the best installation position to ensure stable

sensing. (Refer to the table above.) The best installation posi-

tion depends on the object to be detected.

Figure 1 illustrates the correct way to install the SA1J. The

sensing direction in Figure 1 is less affected by changes in

the sensing angle than the sensing direction in Figure 2. The

sensor should be oriented so that the object moves in the

direction shown in Figure 3.

Part Number

a

b

c

SA1J-C1

¨¨

1.97" 
(50mm)

3.25" 
(82.5mm)

0.40" 
(10.2mm)

SA1J-C2

¨¨

0.79" 
(20mm)

2.11" 
(53.5mm)

0.10" 
(2.5mm)

2.68" (68mm)

0.69" 

(17.6mm)

2.59" (65.7mm)

Do not use the sensor in extremely dusty areas or areas sub-

ject to strong shocks or vibrations. In addition, do not use the

sensor near the following:

• Induction machines and heat sources

• Oil and chemicals

• Corrosive gasses

•  Water (for a long period of time)

Do not expose the receiver to excessive extraneous light.

Use a soft cloth dipped in alcohol to remove dust from the

sensing area on the front of the sensor. To avoid damaging

the sensor, do not use organic solvents for cleaning.

To avoid damaging the sensor, do not tighten the mounting

screws excessively. The maximum tightening torque for the

mounting screws should be less than 2.0N·m.

Do not apply excess voltage between the power supply and

the housing.

When installing SA1J sensors in parallel, maintain at least

30mm spacing between units.

When closing the cover, the tightening torque should range

from 0.49N·m to 0.69N·m. Do not allow dust to accumulate

inside the operation cover, because the degree of protection

(IP67) may be impaired.

The turning torque for the inspection tolerance dial should

not exceed 0.02N·m.

The operating force for the reference color set button should

not exceed 30N.

Installation

Connect wiring according to the diagrams on the following

page. Miswiring will cause damage.

The power voltage should not exceed the rated range.

Do not install high-voltage and power lines in the same con-

duit as the input and output lines. Use separate conduits.

If wires are long, power lines and electromagnetic equipment

may interfere with the sensor’s operations. Use a separate

conduit for wiring.

When using a switching power supply, be sure to ground the

FG (frame ground) terminal.

Cable extension is allowed up to 100m using a cabtyre cable

with core wires of 22 AWG or more.

Standard Installation

Installation Notes

Safety Information

Wiring

1- and 3-Color Types

Input Circuit

TREICHL-ATM Electronic    Auf der Bült 10 - 12      D 41189 Mönchengladbach 

Tel. 02166 958545     Fax 02166 958547 

 

 

 eMail: [email protected]    internet: www.lichtschranke.de

Содержание SA1J-C1NQ

Страница 1: ...and dead parts 1 000V AC 1 minute Insulation Resistance Between live and dead parts 20M minimum 500V DC megger Operating Temperature 10 to 50C performance will be adversely affected if the sensor bec...

Страница 2: ...or Synchronous Mode Selectable Internal response mode or synchronized with an external signal Response Mode High speed F 0 3ms Normal speed N 1ms Slow speed S 5ms High speed F 0 8ms Normal speed N 1 5...

Страница 3: ...te Detects marks regardless Choose between a small spot 2 5mm or a standard spot 8mm with a long distance range of similarity of color Cap Liner SA1J SA1J IDEC IDEC Checking packaging labels for corre...

Страница 4: ...response is activated when INT is selected and the refer ence color set button is pressed Same color Different color Detected object External synchronous Signal On Off Output Response time t t 1 In th...

Страница 5: ...necessary to distinguish between slight variations in shade Synchronous mode switch Select external or internal External synchronous mode EXT External EXT is used to synchro nize inspection with an ex...

Страница 6: ...ions below to register the reference color using the Reference Color Set Button 1 Set the synchronous mode to INT 2 Set the reference color selector dial to A Aim the sensor at color target A and then...

Страница 7: ...maging the sensor do not use organic solvents for cleaning To avoid damaging the sensor do not tighten the mounting screws excessively The maximum tightening torque for the mounting screws should be l...

Страница 8: ...ET Set input Violet EXT External synchronous input Black OUT A Control output A White OUT B Control output B Gray OUT C Control output C Lead Wire Brown Blue Pink Violet Black Gray White V Brown SET P...

Отзывы: