Viceroy GT -
Installation & Servicing
GENERAL
Flow Connection
in.
3
3
3
4
4
4
4
Return Connection
in.
3
3
3
4
4
4
4
Drain Connection
in.
2
2
2
2
2
2
2
Maximum Operating Pressure
bar
6
6
6
6
6
6
6
Boiler Thermostat Setting
ºC
30 - 90
30 - 90
30 - 90
30 - 90
30 - 90
30 - 90
30 - 90
Safety Thermostat Setting
ºC
110
110
110
110
110
110
110
High / Low Setting
ºC
30 - 90
30 - 90
30 - 90
30 - 90
30 - 90
30-90
30-90
Nominal Flue
m m
250
250
250
300
300
300
300
Diameter
in.
10
10
10
12
12
12
12
Boiler Water
l
366
409
452
495
538
581
624
Content
gal
80.5
89.9
99.4
109
118.4
127.8
137.3
Boiler DRY Weight
kg
1941
2027.5
2524
2492
2652.5
2881
3117
less Burner Unit
lb
4280
4470.5
5565
5494.5
5849
6353
6873
Maximum
m
3
/h
44.78
51.74
61.88
69.06
77.11
82.87
89.77
Gas Rate
ft
3
/h
1582
1827
2185
2439
2723
2927
3170
Maximum Flue
m
3
/s
0.279
0.322
0.386
0.429
0.479
0.515
0.558
Gas Volume
ft
3
/min
591
682
818
909
1015
1091
1182
Flue Gas CO
2
/ Temperature
% / ºC
9.5 / 220
9.5 / 220
9.5 / 220
9.5 / 220
9.5 / 220
9.5 / 220
9.5 / 220
Note
.
Fuel rates and flue gas data relate to maximum output ratings.
Gas firing data relates to the use of NATURAL GAS ONLY.
Details for the use of LPG are available on request from Caradon
Ideal Ltd.
Natural gas consumption is calculated using a calorific value of
38.7MJ/m
3
(1038Btu/ft
3
) gross or 34.9MJ/m
3
(935Btu/ft
3
) nett at
15ºC and 1013.25mbar.
Oil rates relate to Gas Oil using a calorific value of 45.56 MJ/kg
gross or 42.69 MJ/kg nett.
Table 1 Performance Data
Boiler
GT 8
GT 9
GT 10
GT 11
GT 12
GT 13
GT 14
Number of Sections
8
9
10
11
12
13
14
Maximum
kW
390
450
540
600
670
720
780
Heat Output
Btu/hx10
3
1330
1535
1842
2047
2286
2457
2661
Minimum
kW
300
390
450
540
600
670
720
Heat Output
Btu/hx10
3
1024
1330
1535
1842
2047
2286
2457
Hydraulic
mbar
31.6
49.3
75.9
84.2
104.9
127.9
161.4
Resistance at 11k
in w.g.
12.6
19.7
30.3
33.7
42.0
51.2
64.6
Hydraulic
mbar
9.6
14.9
23.0
25.5
31.7
38.7
48.8
Resistance at 20k
in w.g.
3.8
6.0
9.2
10.2
12.7
15.5
19.5
Combustion Chamber
mbar
1.1
1.5
2.0
2.5
2.5
2.5
3.5
Resistance (at zero draught)
in w.g.
0.44
0.6
0.8
1.0
1.0
1.0
1.4
Minimum Draught at Smokehood mbar
0
0
0
0
0
0
0
Outlet (for max. output)
in w.g.
0
0
0
0
0
0
0
HEALTH & SAFETY DOCUMENT NO. 635
The electricity at work regulations, 1989
. The manufacturer's
notes must NOT be taken, in any way, as overriding statutory
obligations.
IMPORTANT
. These appliances are CE certified for safety and
performance. It is, therefore, important that no external control
devices, e.g. flue dampers, economisers etc., are directly
connected to these appliances unless covered by these
Installation and Servicing Instructions or as otherwise
recommended by
Caradon Ideal Limited
in writing. If in doubt
please enquire.
Any direct connection of a control device not approved by
Caradon Ideal Limited
could invalidate the certification and the
normal appliance warranty. It could also infringe the Gas Safety
Regulations and the above regulations.
Maximum
l/h
43.08
49.76
59.51
66.42
74.17
79.71
86.35
Oil Rate
gal/h
9.48
10.95
13.09
14.61
16.32
17.54
19.00
Maximum Flue
m
3
/s
0.252
0.290
0.348
0.387
0.432
0.465
0.503
Gas Volume
ft
3
/min
534
614
737
820
915
985
1065
Flue Gas CO
2
/ Temperature
% / ºC
13 / 220
13 / 220
13 / 220
13 / 220
13 / 220
13 / 220
13 / 220
Oil
Table 2 General Data
Gas