5 Boiler Resets in 15 minutes

1. Turn electrical supply to boiler off and on.

2. If the boiler fails to operate please contact Ideal (if under warranty) or alternatively 

a Gas Safe Registered Engineer if outside of the warranty period.  In IE contact a 
Registered Gas Installer (RGII).

False Flame Lockout

Restart the appliance - if the boiler fails to operate then please contact Ideal (if under 
warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty 
period.  In IE contact a Registered Gas Installer (RGII).

BCC Activation Fault

Restart the appliance - if the boiler fails to operate then please contact Ideal (if under 
warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty 
period.  In IE contact a Registered Gas Installer (RGII).

diSPlAy Code on boileR

deSCRiPtion

Low Water Pressure

ACtion

Check system water pressure is between 1 & 1.5bar on the system pressure gauge (G).  
To re-pressurise the system see Section 3.  If the boiler still fails to operate then please 
contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside 
of the warranty period.  In IE contact a Registered Gas Installer (RGII).

Check system water pressure is between 1 & 1.5bar on the system pressure gauge (G).  
To re-pressurise the system see Section 3.  If the boiler fails to operate then please contact 
Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the 
warranty period.  In IE contact a Registered Gas Installer (RGII).

9. 

fAUlt CodeS

Flow Temperature Overheat 
or No Water Flow 

BCC Fault

Flame Loss

Flame Loss

1. Check other gas appliances in the house are working to confirm a supply is present in 

the property.

2. If other appliances do not work or there are no other appliances, check the gas supply 

is on at the meter and/or pre payment meter has credit.  If the boiler fails to operate then 
please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer 
if outside of the warranty period.  In IE contact a Registered Gas Installer (RGII).

1. Check other gas appliances in the house are working to confirm a supply is present in 

the property.

2. If other appliances do not work or there are no other appliances, check the gas supply 

is on at the meter and/or pre payment meter has credit.  If the boiler fails to operate then 
please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer 
if outside of the warranty period.  In IE contact a Registered Gas Installer (RGII).

Fan Fault

Restart the appliance - if the boiler fails to operate then please contact Ideal (if under 
warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty 
period.  In IE contact a Registered Gas Installer (RGII).

Flow Thermistor

Restart the appliance - if the boiler fails to operate then please contact Ideal (if under 
warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty 
period.  In IE contact a Registered Gas Installer (RGII).

Return Thermistor

Restart the appliance - if the boiler fails to operate then please contact Ideal (if under 
warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty 
period.  In IE contact a Registered Gas Installer (RGII).

Outside Sensor Failure

Restart the appliance - if the boiler fails to operate then please contact Ideal (if under 
warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty 
period.  In IE contact a Registered Gas Installer (RGII).

Low Mains Voltage

Contact a qualified electrician or your electricity provider.

Unconfigured PCB

Unconfigured PCB.  Please contact Ideal (if under warranty) or alternatively a Gas Safe 

Registered Engineer if outside of the warranty period.  In IE contact a Registered Gas 
Installer (RGII).

Содержание Independent C24

Страница 1: ...e reconditioned or copy parts that have not been clearly authorised by Ideal For the very latest copy of literature for specification and maintenance practices visit our website www idealboilers com w...

Страница 2: ...electrical installation It is essential that the instructions in this booklet are strictly followed for safe and economical operation of the boiler Electricity Supply This appliance must be earthed Su...

Страница 3: ...f Set the mode knob D to boiler off The boiler mains power supply must be left on to enable frost protection see Frost Protection Preheat Domestic Hot Water The domestic hot water heat exchanger withi...

Страница 4: ...gnite call your Gas Safe Registered engineer Preventative solutions During cold weather set the central heating temperature knob C to maximum Must return to original setting once cold spell is over Pl...

Страница 5: ...once a year by a Gas Safe Registered Engineer or in IE a Registered Gas Installer RGII 6 Mechanical 24 Hour Timer 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 13 1 4 1 5 1 6 1 7 1 8 19 2 0 2 1 22 23 24 GRASSLIN 3G99...

Страница 6: ...eck the time settings on the programmer are as you require and adjust if necessary Check the programmer internal or external to the boiler is in an ON position and the room thermostat is turned up NO...

Страница 7: ...t water but the appliance has reached the desired temperature set on the boiler The boiler is operating in central heating The boiler is operating in domestic hot water preheat The boiler is operating...

Страница 8: ...the gas supply is on at the meter and or pre payment meter has credit If the boiler fails to operate then please contact Ideal if under warranty or alternatively a Gas Safe Registered Engineer if outs...

Отзывы: