3.   SySteM WAteR PReSSURe

The system pressure gauge (G - see 
page 3) indicates the central heating 
system pressure. If the pressure is seen 
to fall below the original installation 
pressure of 1-2 bar over a period of 
time and continue to fall then a water 
leak may be indicated. In this event re-
pressurise the system.  If unable to do so or if the pressure 
continues to drop a Gas Safe Registered Engineer or in IE a 
Registered Gas Installer (RGII) should be consulted.  

THE BOILER WILL nOT OPERATE If THE PREssuRE 

HAs REduCEd TO LEss THAn 0.3 BAR undER THIs 

COndITIOn.

4. 

CondenSAte dRAin

This appliance is fitted with a siphonic condensate trap 

system that reduces the risk of the appliance condensate 

from freezing.  However should the condensate pipe to this 

appliance freeze, please follow these instructions:

a.  If you do not feel competent to carry out the defrosting 

instructions below please call your local Gas Safe 
Registered installer for assistance.

b.  If you do feel competent to carry out the following instructions 

please do so with care when handling hot utensils.  Do not 
attempt to thaw pipework above ground level.

If this appliance develops a blockage in its condensate pipe, 
its condensate will build up to a point where it will make a 
gurgling noise prior to locking out an “L2” fault code.  If the 
appliance is restarted it will make a gurgling noise prior to it 
locking out on a failed ignition “L2” code.

To unblock a frozen condensate pipe;

1.  Follow the routing of the plastic pipe from its exit point on 

the appliance, through its route to its termination point.

  Locate the frozen blockage.  It is likely that the pipe is 

frozen at the most exposed point external to the building 

or where there is some obstruction to flow.  This could be 

at the open end of the pipe, at a bend or elbow, or where 
there is a dip in the pipe in which condensate can collect.  

The location of the blockage should be identified as 

closely as possible before taking further action.

2.  Apply a hot water bottle, microwaveable heat pack or a 

warm damp cloth to the frozen blockage area.  Several 

applications may have to be made before it fully defrosts.  
Warm water can also be poured onto the pipe from a 
watering can or similar.  DO NOT use boiling water.

3.  Caution when using warm water as this may freeze and 

cause other localised hazards.

4. 

Once the blockage is removed and the condensate can flow 

freely, restart the appliance. (Refer to “To Light the boiler”)

5.  If the appliance fails to ignite, call your Gas Safe 

Registered engineer.

Preventative solutions

During cold weather, set the central heating temperature knob 
(C) to maximum, (Must return to original setting once cold 
spell is over).

Place the heating on continuous and turn the room 
thermostat down to 15ºC overnight or when unoccupied. 
(Return to normal after cold spell).

effiCient HeAtinG SySteM oPeRAtion

The boiler is a high efficiency, condensing appliance which will 

automatically adjust its output to match the demand for heat.  
Therefore gas consumption is reduced as the heat demand is 
reduced.

The boiler condenses water from the flue gases when operating 

most efficiently.  To operate your boiler efficiently (using less gas) 

turn the central heating temperature knob (C) to the ‘   ‘ position 
or lower.  In winter periods it may be necessary to turn the knob 
towards the ‘

max

’ position to meet heating requirements.  This will 

depend on the house and radiators used.

Reducing the room thermostat setting by 1ºC can reduce gas 
consumption by up to 10%.

WeAtHeR CoMPenSAtion

When the Weather Compensation option is fitted to the system then 

the central heating temperature knob (C) becomes a method of 
controlling room temperature.  Turn the knob clockwise to increase 
room temperature and anti-clockwise to decrease room temperature.  
Once the desired setting has been achieved, leave the knob in this 
position and the system will automatically achieve the desired room 
temperature for all outside weather conditions.

boileR fRoSt PRoteCtion

The boiler is fitted with frost protection that operates in all modes, 

provided the power supply to the boiler is always turned on.  If 
the water in the boiler falls below 5ºC, the frost protection will 

activate and run the boiler to avoid freezing.  The process does not 

guarantee that all other parts of the system will be protected. 

If a system frost thermostat has been installed, the boiler must be 

set in winter mode, ‘ 

 ’, for the system frost protection to run.

If no system frost protection is provided and frost is likely during a 
short absence from home it is recommended to leave the system 

heating controls or built in programmer (if fitted) switched on and 

run at a reduced temperature setting. For longer periods, the entire 
system should be drained.

boileR ReStARt

To restart the boiler, when directed in the listed fault codes (see 
section 9), turn the mode knob (D) to ‘

restart

’ position and 

IMMEDIATELY turn knob back to required setting.  The boiler will 
repeat its ignition sequence.  If the boiler still fails to start consult a 
Gas Safe Registered Engineer or in IE a Registered Gas Installer 
(RGII).

MAinS PoWeR off

To remove all power to the boiler the mains power switch must be 
turned off.

Содержание Independent C24

Страница 1: ...e reconditioned or copy parts that have not been clearly authorised by Ideal For the very latest copy of literature for specification and maintenance practices visit our website www idealboilers com w...

Страница 2: ...electrical installation It is essential that the instructions in this booklet are strictly followed for safe and economical operation of the boiler Electricity Supply This appliance must be earthed Su...

Страница 3: ...f Set the mode knob D to boiler off The boiler mains power supply must be left on to enable frost protection see Frost Protection Preheat Domestic Hot Water The domestic hot water heat exchanger withi...

Страница 4: ...gnite call your Gas Safe Registered engineer Preventative solutions During cold weather set the central heating temperature knob C to maximum Must return to original setting once cold spell is over Pl...

Страница 5: ...once a year by a Gas Safe Registered Engineer or in IE a Registered Gas Installer RGII 6 Mechanical 24 Hour Timer 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 13 1 4 1 5 1 6 1 7 1 8 19 2 0 2 1 22 23 24 GRASSLIN 3G99...

Страница 6: ...eck the time settings on the programmer are as you require and adjust if necessary Check the programmer internal or external to the boiler is in an ON position and the room thermostat is turned up NO...

Страница 7: ...t water but the appliance has reached the desired temperature set on the boiler The boiler is operating in central heating The boiler is operating in domestic hot water preheat The boiler is operating...

Страница 8: ...the gas supply is on at the meter and or pre payment meter has credit If the boiler fails to operate then please contact Ideal if under warranty or alternatively a Gas Safe Registered Engineer if outs...

Отзывы: