PHYSICAL MOUNTING 

1.

 

The GW1100 Wireless Gateway can be mounted on a wall or surface using the screws 
provided.  Refer to Figure 1 for mounting hole dimensions.  It is important to keep the 
external antennas oriented vertically, regardless of the orientation of the gateway 
enclosure.  See Figures 2 and 3 for orientation examples.  Alternately, the GW1100 
Wireless Gateway can be set atop a desk or countertop anywhere.   

2.

 

The GW1100 requires a 24VDC input.  This can be achieved via a PSU1500 power 
supply (sold separately) or by wiring 24VDC directly into the power connector on the 
unit.  See Figure 4 for details. 

3.

 

To connect the GW1100 to your office network, insert an Ethernet cable into the 
Ethernet port on the side of the unit.  See Figure 5 for details. 

 

*Dimensions in inches

 

Figure 1: Horizontal Mount, Top View

 

Содержание GW1100

Страница 1: ...S and or a dedicated internet interface e g website or app It then communicates wirelessly with each Smart Connector to turn on turn off or dim light fixtures based on input from the systems above The...

Страница 2: ...ented vertically regardless of the orientation of the gateway enclosure See Figures 2 and 3 for orientation examples Alternately the GW1100 Wireless Gateway can be set atop a desk or countertop anywhe...

Страница 3: ...ct Manual GW1100 Wireless Gateway ND 7944 2 02 2014 Users Manual GW1100 Wireless Gateway Page 3 www idealindustries com Figure 2 Horizontal Mount Antennas Extended Figure 3 Vertical Mount Antennas Ext...

Страница 4: ...Manual GW1100 Wireless Gateway ND 7944 2 02 2014 Users Manual GW1100 Wireless Gateway Page 4 www idealindustries com Figure 4 Gateway Power Input Figure 5 Gateway Ethernet Input 24V Power Input Ethern...

Страница 5: ...ble terminal block Configuration Port Ethernet Network Port Ethernet RS 485 or FTT 10 Operating Temperature 10 C to 32 C Storage Temperature 20 C to 50 C Installation Environment Indoor use only Mount...

Страница 6: ...e user will be required to correct the interference at his own expense This device is intended for commercial and industrial applications Changes or modifications not expressly approved by IDEAL could...

Страница 7: ...rademarks are the property of their respective owners IDEAL INDUSTRIES INC PRODUCTS INCLUDING HARDWARE AND OR SOFTWARE ARE NOT DESIGNED OR INTENDED TO BE FAIL SAFE FAULT TOLERANT OR FOR USE IN ANY APP...

Страница 8: ...EAL Customer may not return products without first obtaining a customer return material authorization RMA number from IDEAL THE WARRANTIES SET FORTH HEREIN ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRA...

Отзывы: