4
Concord Super Series 4 -
Installation & Servicing
TECHNICAL DATA
Table 1
Boiler
50 V
100 V
150 V
200 V
250 V
300 V
150 VA 250 H
300 H
No. of modules
1
2
3
4
5
6
3
5
6
Heat output
kW
50
100
150
200
250
300
150
250
300
Btu/h x 10
3
170.6
341.2
511.8
682.4
853.0
1023.6
511.8
853.0
1023.6
Heat input
kW
58.8
117.6
176.4
235.2
294.0
352.8
176.4
294.0
352.8
Btu/h x 10
3
200.6
401.3
601.9
802.5
1003.1 1203.8
601.9
1003.1 1203.8
Gas rate
m
3
/h
5.5
11.0
16.5
22.1
27.6
33.1
16.5
27.6
33.1
ft.
3
/h
195
389
584
779
973
1168
584
973
1168
Flue gas mass
volume *
at 120ºC (248ºF)
g/s
25
50
75
100
125
150
75
125
150
l/s
27
55
82
110
137
164
82
137
164
ft.
3
/min
58
116
174
232
290
348
174
290
348
Required water
flow rate ± 10%
l/s
1.07
2.14
3.21
4.28
5.35
6.42
3.21
5.35
6.42
gal./min.
14.1
28.2
42.3
56.4
70.5
84.6
42.3
70.5
84.6
Hydraulic resistance
12.5 kN/m
2
(50 in w.g.)
Maximum static head**
2 m (6.5 ft.)
Maximum static head
60.0 m (197 ft.) 6.0 bar (85 lb/in
2
)
Electricity supply
230 V ~ 50Hz,
Power consumption
W
90
180
270
360
450
540
270
450
540
Gas supply pressure
20.0 mbar (8 in. w.g.)
Boiler height
(overall)
mm
782
1432
1912
1550
2060
2060
1550
1480
1480
in.
30.8
56.4
75.3
61.0
81.1
81.1
61.0
58.3
58.3
Boiler width
(overall)
m m
475
942
955
1425
1441
1441
1425
1817
1817
in.
18.7
37.1
37.6
56.1
56.7
56.7
56.1
71.5
71.5
Boiler depth (overall)
698 mm (27.4 in.)
Weight of casing
and insulation
kg.
29.1
47.7
61.5
76.6
106.6
98.9
84.0
107.0
99.0
lb.
64.1
105.2
135.5
168.8
235.0
218.0
185.0
235.0
218.0
Weight of
modules
kg.
53
106
159
212
265
318
159
212
318
lb.
116
232
348
464
580
696
348
580
696
Weight of gas &
water headers
kg.
-
34.0
53.6
59.4
89.4
94.3
53.4
92.2
96.7
lb.
-
75
118
131
197
200
118
203
213
Water content
boiler
l.
4.5
11.9
20.7
26.2
37.7
44.5
21.7
39.7
44.5
gal.
1.0
2.6
4.6
5.9
8.3
9.9
4.9
8.8
9.9
Flow and return
connection
mm
40
50
65
65
80
80
65
80
80
in.
1
1
/
2
2
2
1
/
2
2
1
/
2
3
3
2
1
/
2
3
3
Gas connection
Rc
3
/
4
1
1
1
/
4
1
1
/
4
1
1
/
2
1
1
/
2
1
1
/
4
1
1
/
2
1
1
/
2
in. BSP
3
/
4
1
1
1
/
4
1
1
/
4
1
1
/
2
1
1
/
2
1
1
/
4
1
1
/
2
1
1
/
2
Flue pipe size
(nominal bore)
mm
125
175
200
250
250
300
200
250
300
in.
5
7
8
10
10
12
8
10
12
Flue socket size
mm
159
213
238
288
288
339
238
288
339
in.
6
1
/
4
8
3
/
8
9
3
/
8
11
3
/
8
11
3
/
8
13
3
/
8
19
3
/
8
11
3
/
8
13
3
/
8
Injector size
7.3 mm (0.28 in.)
Type of gas
Natural gas (G20 only)
* Flue gas volumes are calculated from a calorific
value of 38.4 MJ/m
3
(1,031 Btu/ft.
3
) at 15ºC and
1.013 bar - based on a CO
2
content of 9.0%.
** For further information on minimum head
requirements refer to page 10.
Notes.
Total weights of all headers, fully assembled.
The minimum gas supply pressure is with all modules firing.
Flange size; refer to BS.4504.
For 150 VA, 250 V and 250 H models ONLY, a flue adaptor is
supplied as standard.