Installation
INTRODUCTION
The
Classic RS 230-260
(standard) and
Classic LXRS 230 -
260
(deluxe model) is a range of automatically fully controlled,
wall mounted, balanced flue, gas boilers.
The boiler casing is of white enamelled mild steel.
The boilers are supplied with a standard flue kit, suitable for rear
outlet applications from 229mm (9") to 305mm (12").
The boilers are suitable for connection to pumped, open vented
central heating systems; pumped central heating combined with
pumped or gravity indirect domestic hot water systems; gravity
or pumped indirect domestic hot water supply systems.
See Frame 1 for details of the correct boiler tappings to use.
LXRS 230-260 (Deluxe model)
The boiler casing is fitted with a glass fascia. The glass fascia
can be lifted up to gain access to the boiler thermostat.
RS 230-260 (Standard model)
The boiler casing has a removable controls pod containing a
drop-down door. The boiler thermostat is located behind the
drop-down door.
All details for the deluxe jacket model are the same as the
standard model, unless otherwise stated.
OPTIONAL EXTRA KITS
Programmer kit
fits neatly within the casing. Separate
fitting instructions are included with this kit.
Extension ducts
up to 585 mm (23").
Overheat
allows the boiler to be used on sealed
Thermostat Kit
systems.
Sealed System
fits on top of the appliance (suitable
Unit
for Standard models only)
The installation of the boiler MUST also be in accordance with
the latest I.E.E (BS 7671) Wiring Regulations, local building
regulations, bylaws of the local water authority, the Building
Regulations and Building Standards (Scotland) and any relevant
requirements of the local authority.
Detailed recommendations are contained in the following British
Standard Codes of Practice:
BS. 6891
Low pressure installation pipes.
BS. 6798
Installation of gas fired hot water boilers of rated
input not exceeding 60 kW.
BS. 5449
Forced circulation hot water systems.
BS. 5546
Installation of gas hot water supplies for domestic
purposes (2nd Family Gases).
BS. 5440: Part 1 Flues for gas appliances of rated input not
exceeding 60 kW.
BS. 5440: Part 2 Ventilation for gas appliances of rated input
not exceeding 60 kW.
BS 7593
Treatment of water in Domestic Hot Water Central
Heating Systems.
Health & Safety Document No. 635.
The Electricity at Work Regulations, 1989.
Manufacturer’s notes must NOT be taken in any way as
overriding statutory obligations.
IMPORTANT.
These appliances are certificated by the British
Standards Institution for safety and performance. It is important,
therefore, that no external control devices, e.g. flue dampers,
economisers etc., are directly connected to these appliances
unless covered by these ‘Installation and Servicing’ instructions
or otherwise recommended by
Caradon Plumbing Limited
in
writing. If in doubt please enquire.
Any direct connection of a control device not approved by
Caradon Plumbing Limited
could invalidate the BSI
Certification and the normal appliance warranty. It could also
infringe the Gas Safety Regulations and the above regulations.
LOCATION OF BOILER
The boiler must be installed on a flat and vertical wall, capable
of adequately supporting the weight of the boiler and any
ancillary equipment.
The boiler may be fitted on a combustible wall and insulation
between the wall and the boiler is not necessary - unless
required by the local authority.
The boiler must not be fitted outside.
GENERAL
NOTE TO THE INSTALLER: LEAVE THESE
INSTRUCTIONS ADJACENT TO THE GAS METER.
ALSO COMPLETE THE BENCHMARK LOG BOOK
AND GIVE THIS TO THE CUSTOMER.
GAS SAFETY (INSTALLATION AND USE) Regulations
1994, amendments 1996 or rules in force.
It is law that
all
gas appliances are installed by a CORGI
registered installer (identified by
) in accordance with the
above regulations. Failure to install appliances correctly could
lead to prosecution. It is in your own interest, and that of safety,
to ensure the law is complied with.