18
INSTALLATION
Classic
Slimline FF
-
Installation & Servicing
SIDE FLUE OUTLET
1.
The boiler is supplied for
rear outlet installation.
Remove the blanking plate
from the direction required
and use this to blank off the
rear outlet.
2.
Lift the boiler onto the wall
mounting plate, as shown.
Do not use the burner/
controls for lifting.
3.
Fit the No. 14 x 50mm
wood screw, washer and
rectangular plate to retain
the boiler.
Note.
Before fully tightening
the retaining screw check the
boiler alignment using a spirit
level and adjust as necessary
with the jacking screw.
1.
Fix the mounting plate to the wall with the No.14 x 50mm
wood screws.
2.
Check with a spirit level that the plate is horizontal.
28 FITTING THE SIDE OUTLET PLATES
30 MOUNTING THE BOILER
Note.
If the boiler is fitted closer than 25mm to the side wall
the side outlet plate must be fitted now.
1.
Split the side outlet plate into 2 down the split line.
2.
Fit the 2 halves of the side outlet plate to the wall,
ensuring they are behind the boiler sealing ring.
29 WALL MOUNTING PLATE
3. Cupboard Supports
In some applications existing wooden supports my hinder
the removal of the casing. Two cupboard supports are
provided for the top and bottom of the opening. These
should be positioned to allow the casing to be removed
in servicing.