12
Mode Button
Pressing the mode button after a scan (while keeping the trigger pulled)
allows you to see the Max, Min, Average, and Difference values in the
secondary display screen.
Measured Surface Outline
A single press of the trigger results in a single area temperature of the surface
outlined by the two laser dots.
Set Button
Pressing the SET button allows you to configure Hi and Low Temperature
alarms, emissivity, degrees F or C, audible alarm, auto off time, and lock
measurement setting.
Scanning
Pressing the trigger quickly places the unit in scan mode which constantly
updates the temperature reading in the display as you aim at different targets.
SCAN will appear in screen.
Operating Features
Power On
A Single Trigger pull turns the unit on and temperatures are immediately
calculated and the IRT displays the temperature of the surface it is pointed at.
(Between the two laser dots).
Taking a Reading
1. Pull and hold the trigger after aiming at the target. The SCAN icon will be
flashing indicating that the target object temperature is being measured.
The measurement result will be updated on the LCD.
2. Release the trigger, the SCAN icon disappears, and the HOLD icon
appears, indicating that the measurement has been stopped and the last
measured value is held.
Viewing the Last Measured Value
When the unit is off, a short press (less than 0.5s) of the trigger turns the
thermometer on and the last measured temperature before the last shutdown
will be displayed. Toggle to view the MAX/MIN/AVG/DIF values by short
pressing the MODE button.
Meter Operation
MAX
F
HOLD
LO
HI
=
3
F
LO
HOLD
MAX
HI
=
3
Function Setting
In the HOLD interface, short press the SET button to enter the settings of high
alarm limit > low alarm limit emissivity > temperature unit > audible alarm >
lock measurement, etc. In these setting interfaces, pull the trigger or do not
operate for 10 seconds to return to the HOLD interface.
Содержание 61-847
Страница 7: ...6 7 4 1 3 6 7 2 5 6 8 ...
Страница 17: ...16 17 Best Accuracy Coverage Average Accuracy Coverage Poor Accuracy Coverage ...
Страница 33: ...32 33 4 1 3 6 7 2 5 6 8 ...
Страница 43: ...42 43 Mejor Cobertura de Precisión Cobertura de Precisión Media Cobertura de Precisión Deficiente ...
Страница 59: ...58 59 4 1 3 6 7 2 5 6 8 ...
Страница 78: ...78 Notes ...