background image

 CAUTION!

The thermostat must not be left unsupervised 
when open. (Prevent non specialists and especially 
children from gaining access to it.)

Only qualified electricians or authorised service 
staff are permitted to open the thermostat. 

If the thermostat is used in a way not specified by 
the manufacturer, its safety may be impaired.

Operating Instructions

Page 1 of 3

RFRP Room Thermostat 

Wireless

4.  Installation

1.  Factory default settings

6. LCD Symbol / button description

5. Frost protection

2.  Specifications & wiring

Temperature indicator: 

°C

Switching differential:  

0.4°C

In built frost protection: 

5°C - Not adjustable

Clock:  

 

 

24 hours

Keypad lock: 

 

Off

Operating mode: 

 

5/2 day

5°C

Manual

mode

Off mode

Program mode

Set Date/ Time

Holiday mode

Copy function

Boost mode

Automatic 

mode

(Back)

OK confirm button

Set point increase

Set point decrease

Reset button

Operating mode

Current program

Day / Month

Day of the week

Temperature

Battery low symbol

Wireless symbol

Heating on symbol

Keypad lock symbol

Wireless connect button

Current Time

(Boost to time)

3.  Mounting 

     

 Contents 

1.  Factory default settings

2.   Specifications & wiring

3.   Mounting

4.   Installation

5.  Frost protection

6.   LCD symbol / buttons description

7.   Resetting the thermostat

8.   Keypad lock and unlock

9.  Setting the date, time and operating mode

10.  Factory program settings

11.  Adjusting the program settings for 5/2d

12.  Copy Function

13.  Temporary override

14.  Permanent override 

15.  Boost function

16.  Holiday function

17.  To connect the RFRP thermostat to an RF1A receiver

18.  To disconnect the RFRP thermostat from an RF1A receiver

19.  Backlight mode selection

20.  Battery low warning

21.  Replacing the batteries

Prior to setting the thermostat, it is neccessary to 

complete all required settings described in this section.

6.1 LCD Symbol description

6.2 Button description

Important: Keep this document

Power supply: 

 

2 x AA Alkaline Battery

Power consumption:   

2 mW

Battery replacement:   

Once a year

Temp. control range:   

5 ... 35°C

Ambient temperature:  

0 ... 50°C

Dimensions: 

 

130 x 99 x 25mm

Temperature sensor:    

NTC 10K Ohm @ 25°C

Temperature indication: 

˚C 

Switching differential:  

0.4˚C

Frost protection: 

 

Only operational in OFF mode

20170816_RFRP_OpI

ns_JW

EPH Controls Ireland

Sitecast Industrial Estate, Pouladuff,
Cork, T12 W665, Ireland

[email protected]    www.ephcontrols.com

EPH Controls UK

Unit E4, Welland Business Park, Valley Way, Market Harborough, 
Leicestershire, LE16 7PS, United Kingdom

[email protected]   www.ephcontrols.co.uk

The mounting height should be 1.5 meters above the floor level.
The thermostat should be wall mounted in the room where the heating is to 
be controlled.
The place of installation should be chosen so that the sensor can measure the 
room temperature as accurately as possible.
Choose the mounting location to prevent direct exposure to sunlight or other 
heating / cooling sources when mounted.
The unit can be fitted to: 

1. Recessed conduit boxes.

 

 

 

2. Directly on walls.

 

 

 

3. Table mounting with stand provided.

Frost protection is built into this thermostat.
It is pre fixed at 5°C and is not adjustable.
It will only be activated when the thermostat is in the OFF mode and the 
room temperature falls below 5°C.

Lower the flap at the front of the thermostat. 
There is a battery compartment located below the buttons.
Using your 2 thumbs, apply pressure and pull downwards to remove the cover. 
Insert the 2 x AA batteries and the thermostat will turn on.
Close the battery compartment. 

AUTO

MAN

OFF

PROG

TIME

HOL

COPY

BOOST

OK

Отзывы: