Inlet Valve
Major Height Adjustment
Remove locking clip by pushing downwards
Loosen valve body anticlockwise adjust to required height, and tighten clockwise
Re-fit locking clip
Minor Height Adjustment
Realise locking device in direction shown.
Adjust top of cup to approximately 7mm below the water line, and rotating float screw
taking top surface of the float to within 2-4mm below top edge of cup.
Engage the locking device in direction shown. Turn on water supply and check water level
position. Use float screw for final adjustment.
A
B
C
D
E
F
F
2
1
D
E
cup
float
screw
float
C
B
A
7
13
12
11
10
9
8
Connect the water supply to the inlet valve. Turn on the water supply and allow the
cistern to fill. Adjust the float on the inlet valve so that the valve stops the flow of water