26
16
HANDLE REMOVAL FOR CARTRIDGE ACCESS
To gain access to either the thermostatic, flow or diverter cartridges, it will be necessary to
remove the appropriate handle.
1.
Carefully prise out the chrome end cap fitted to the handle. Look for a small notch in the handle,
then use a sharp blade to lever the cap out, taking care not to damage the chromed surfaces.
2.
Undo the handle retaining screw using a Phillips screw driver.
3.
Carefully slide the handle off from the cartridge drive spindle.
4.
Slide off the plastic bush from the drive spindle.
5.
Undertake the necessary maintenance work, the reverse this sequence & refit the handles.
6.
Align the handle marker dot(s) to the marking(s) on the mixer body, as shown below.
4
2
3
Handle
dot marker