Table 1 Conditions of use

Note:

Fittings operating outside these con-

ditions cannot be guaranteed by the 

scheme to operate as 

TMV2.

10

MODULATING COMBI BOILER

This thermostatic bath shower mixer is designed for use with modulating 

combination boilers.

When installing on a modulating combination boiler it is sometimes

possible for the interaction of a thermostatic valve with the combi to

cause the boiler to cut out and cut in again, with the result that the

water will become alternatively cold and hot. To overcome this, a 4 L/min

flow regulator should be fitted upstream of the thermostatic valve. 

It should be fitted in any 15mm compression fitting in the dedicated cold supply pipe.

It is important to choose a compression fitting located in a position which is accessible after installation 

and it must be fitted the correct way round for the direction of flow.  The regulator can be fitted in either 

the inlet or outlet side of the compression fitting. If fitting in an outlet side, ensure the o-ring is seated 

fully in the visible rebate around the edge of the regulator.  Use the tip of a small screwdriver or similar 

to achieve this.  Ensure the tail of the pipe is not fouling the regulator (shorten if required) and do up 

the compression fitting as normal. In a minority of cases, where the boiler is of a type which stores a 

small quantity of very hot water, it may also be necessary to fit a 4 l/min flow regulator in the hot supply.

flow direction

through

flow regulator

• 

A pair of service valves (for isolating both water supplies) MUST be fitted below the bath to permit 

future maintenance of this product, 

see sect 23

. These should be fitted as close as practicable to 

the water supply inlets of the mixer & in an easily accessible location.

• 

The mixers include mesh filters (strainer-washers) and check valves are fitted inside the

 

inlets of 

these products, 

see section 20

.

These regulators, spares code A962570NU, can be obtained by contacting

            Ideal Standard Customer Care or www.idealstandard.co.uk

WATER SUPPLY CONDITIONS

BSEN1111

Operating pressure range:

High Pressure

Maximum static pressure

10 bar

Flow pressure hot and cold 1.0 to 5.0 bar
Hot supply temperature

55 to 65 °C

Cold supply temperature

5 to 20 °C max

 

Introduction

These thermostatic shower mixers are manufactured to the highest standards & have approval to TMV2.

The mixer is intended to be installed on high pressure systems (1.0 bar or greater). The mixer has safety 

features such as cool body technolgy and temperature limit stop. To make installation easier, fast fix wall 

mounts are supplied. Ø15mm water supply pipes should be installed at 150mm horizontal centres in the 

wall, behind a shower panel or tiled duct wall.

Excessive flowrate

To remedy an excessive flowrate issue, where the above inlet regulators have not been fitted, we 

recommend the use of a “shower outlet flow regulator”. This is suitable for installations which exceed 2 

bar dynamic pressure.

A 9 litres per minute outlet regulator is available, quote spares code L6749AA.

This regulator can be easily fitted between the shower valve outlet and the shower hose

  

TMV2 products

- A7216AA

- A7221AA

- A7225AA

- A7227AA

Содержание Ceratherm T50

Страница 1: ...es A7225AA A7227AA bar shower mixer dual pack with overhead Rain shower Hand spray Thermostatic exposed two hole rim wall mounted bath shower mixers Ceratherm T50 INSTALLER After installation please p...

Страница 2: ...XER A7224AA 17 7 4 QUICK GUIDE OF SHOWER PACK INSTALLATION A7225AA A7227AA 18 8 OPERATING PRODUCT 19 8 1 A7216AA A7221AA 19 8 2 A7225AA A7227AA 20 8 3 A7224AA A7697AA 20 9 TEMPERATURE ADJUSTMENT 21 10...

Страница 3: ...for A7227AA A7225AA 1 2 Wrap over shower shelves 1 1 A7216AA A7221AA A7225AA A7227AA Wall mount mixers Shown A7216AA bar shower mixer supplied without shower kit Dimensions same for A7221AA bar showe...

Страница 4: ...s assembled Basic bath shower mixer dimensions shown with wall mounting brackets assembled Dimensions are in millimetres may vary within permitted tolerances 1 3 A7224AA Deck mount mixer 1 4 A7697AA W...

Страница 5: ...spray supplied only with these two product 5 Dimensions are in millimetres may vary within permitted tolerances 1 5 SHOWER PACKS Note The following three products do not include a shower pack kit A72...

Страница 6: ...verts between hand spray overhead rain shower Includes dual shower pack shown below 600 Shower rail Handset pack supplied only with A7221AA Includes Idealrain Evo shower kit with three function handsp...

Страница 7: ...lied in this kit for the bath shower mixer The G1 2 thread shown screws into nipples which have been pre fitted in the wall Shower valve shown without wall mounting brackets assembled Mixer supplied w...

Страница 8: ...assembled Supplied only with A7224AA product Right side handle controls flow diverts between bath fill shower hand set Product is supplied without a shower kit 8 2 3 Deck mount mixer A7224AA DO NOT ap...

Страница 9: ...ge tank which feeds the hot water system and the highest point on the shower spray plate When installing with a shower pump the use of a secondary tapping from the cylinder is highly recommended The p...

Страница 10: ...gulator A pair of service valves for isolating both water supplies MUST be fitted below the bath to permit future maintenance of this product see sect 23 These should be fitted as close as practicable...

Страница 11: ...tted zone of backflow risk for restrained hose which is longer than system design hose not permitted zone of backflow risk for unrestrained hose zone of backflow risk for restrained hose w c spill ove...

Страница 12: ...water supply inlets of the mixer in an easily accessible location NOTE service valves are not supplied with thiese products see section 23 Shower Kit The flexible shower hose from the shower kit can...

Страница 13: ...supply pipes should be run within the wall cavity Hot supply pipe should be on the left hand side and the cold on the right Ensure that the hot and cold pipes are positioned 150mm apart and are level...

Страница 14: ...etrically opposed Drill carefully to avoid damaging conce aled pipework 4 5 3 2 Apply a smear of silicone sealant to the rear of the assembled brackets and push them over the pipework Screw both brack...

Страница 15: ...kit 8 9 6 7 15 30 1 2 When the sealant has set fit the covers by screwing them onto the adaptors until they are flush with the wall The covers only need to be hand tight Screw the brass adaptors over...

Страница 16: ...s To achieve a seal apply PTFE tape suitable for water to the G1 2 threads of the S connectors Screw the S Connectors into the nipples as shown Use a spanner on the square flats if necessary As shown...

Страница 17: ...e tails of the legs into the two holes in the bath Align the legs and gently lower the mixer onto the rim of the bath IMPORTANT make sure the deck seals are still correctly located in the recesses of...

Страница 18: ...7 4 Quick guide of shower pack installation A7225AA A7227AA 1 11 4 6 8 7 6 5 2 5 9 2 5 1 3 10 10 11 min 10 Nm min 700 18...

Страница 19: ...about 50 of the maximum flow rate achievable through this product To obtain greater flow rate press hold the right button rotate this handle further downwards The handle will rotate a further 45 from...

Страница 20: ...imum flow rate achievable through this product To obtain greater flow rate press hold the right button rotate this handle further downwards The handle will rotate further to the maximum flow stop Rota...

Страница 21: ...efore sliding the handle off ensure the dot on the handle is inline with the 40 marker on the mixer 4 Slide the handle off the spindle 5 Slide off the plastic bush from the drive spindle 6 Turn on the...

Страница 22: ...check that the temperature is below 45 C If there is no significant change to the set outlet temperature 2 C or less change from the original settings and the fail safe shut off is functioning then t...

Страница 23: ...clean all filters ensure check valves are working and make sure all isolating valves are fully open Refit the shower handset to the flexible hose upon completion of the test NOTE In order to isolate t...

Страница 24: ...se inline service valves if fitted 2 Fully open the flow or diverter handle to confirm water is switched off Unscrew the shower hose from the underside of the mixer This will permit some of the trappe...

Страница 25: ...gely dependent upon the water quality and service life As a minimum we recommend removal both handles thermostatic cartridge flow control or diverter cartridge Cleaning the cartridge strainer screens...

Страница 26: ...then use a sharp blade to lever the cap out taking care not to damage the chromed surfaces 2 Undo the handle retaining screw using a Phillips screw driver 3 Carefully slide the handle off from the car...

Страница 27: ...idge with a new one Alternatively if the cartridge is functioning correctly clean it thoroughly reuse it 5 When fitting the cartridge into the bore ensure the lug on the cartidge is orientated into th...

Страница 28: ...en Align the dot marker on the handle with the line marker on the stop sleeve Reverse the sequence to refit the handle 18 DIVERTER REPLACEMENT 1 Observe disassembling sequence as detailed in section 1...

Страница 29: ...mixer bore screw the cartridge into the mixer body by hand then tighten with a spanner or socket Ideally torque to 16Nm min to 18Nm max 6 Refit the stop ring as illustrated above Align the marked arro...

Страница 30: ...strainers from inside the mixer s inlet bores keep them in a safe location On a regular basis the anti splash nozzle on the bath mixer should be inspected and cleaned if necessary In areas where lime...

Страница 31: ...A 861 373 NU 1 pcs 4 Cartridge G1 2 180 cpl A 861 245 NU 1 Set 5 Nipple G1 2 outside cpl A 861 374 NU 1 Set 6 Non return valve A 861 372 NU 1 Set 7 Escutcheon B 960 242 AA 1 pcs 8 Shower bracket conne...

Страница 32: ...c Cartridge cpl A 861 371 NU 1 pcs 3 Stop valve with diverter A 861 375 NU 1 Set 4 Thread ring stopring cpl A 861 376 NU 1 Set 5 Connection nipple cpl A 861 387 NU 1 Set 6 Non return valve A 861 372 N...

Страница 33: ...42 AA 1 Set 9 Connection nipple cpl A 861 385 NU 1 Set 10 Shower hose 1750 mm BE 175 AA 1 pcs 11 Handspray 110 3F 8l min B 2231 AA 1 pcs 12 Shower bar 1100 mm A 861 377 AA 1 pcs 12 Shower bar 1000 mm...

Страница 34: ...Stop valve with diverter A 861 375 NU 1 Set 4 Thread ring stopring cpl A 861 376 NU 1 Set 5 Connection nipple cpl A 861 387 NU 1 Set 6 Non return valve A 861 372 NU 1 Set 7 Nipple G1 2 outside cpl A...

Страница 35: ...ct MUST be fitted to permit future maintenance of the cartridges They also facilitate the cold water isolation test These should be fitted as close as is practicable to the water supply inlets of the...

Страница 36: ...provements in design performance of its products This right is there fore reserved to vary specification without notice Partial or total reproduction or copying of this manual without our permission i...

Отзывы: