Ideal-Standard Ceratherm T125 Скачать руководство пользователя страница 8

8

INTRODUCTION 

The fittings covered by these instructions should be installed in accord

-

ance with the Water Regulations published in 1999*.  

Ideal Standard strongly recommends that these fittings are installed by 

a professional fitter.

 *A guide to the Water Supply (Water Fittings) Regulations 1999 and the Water Byelaws 2000, Scotland is published 

by WRAS (Water Regulations Advisory Scheme) Unit 13, Willow Road, Pen-y-Fan Industrial Estate, Crumlin, Gwent, 

NP11 4EG.  

ISBN 0-9539708-0-9

WATER REGULATIONS

Hot and cold water supply pressures must be reasonably balanced and from a common source - both 

from storage or both from a supply pipe. (IRN 101).  The mixers will function within specification on 

unequal pressures up to a ratio of 5 : 1, but it is not recommended that the cold supply be connected 

to the rising main and hot to the tank fed supply as the pressure differential is likely to exceed the 5:1 

ratio.  

(See table 1) 

 The minimum pressure for correct operation is 1.0 bar.  Pressure head is measured 

as the vertical distance between the bottom of the cold water storage tank which feeds the hot water 

system and the highest point on the shower spray plate.  When installing with a shower pump the use of 

a secondary tapping from the cylinder is highly recommended.  

The picture below shows the various methods of connecting the hot water pipe to the cylinder - the most 

preferred on the left and the least preferred on the right.

The fitting should be so installed as to be readily accessible for examination, repair, replacement or 

operation. (IRN 111).

The temperature of the hot water must not exceed 85ºC but the installer’s attention is drawn to code 

of practice BS 6700 which recommends that stored hot water should normally never exceed 65ºC. For 

correct operation of the valve, a minimum of 55ºC is required.

most preferred solution

least preferred solution

Essex flange 22mm

Surrey flange

22mm outlet

From vertical

expansion pipe

22mm pipework

Preferred arrangements for cylinder tapping

From underside of

expansion pipe off-set

at 60º 22mm pipe

wo

rk

Note:

 If water supply is fed by gravity then supply pressures should be verified to ensure the 

conditions of use are appropriate for the valve.

Содержание Ceratherm T125

Страница 1: ...ead Rain shower Hand spray Thermostatic exposed two hole rim wall mounted bath shower mixers Ceratherm T125 with lever handles INSTALLER After installation please pass this instruction booklet to user...

Страница 2: ...HOWER PACK INSTALLATION 16 A7594AA 16 8 OPERATING PRODUCT 17 9 TEMPERATURE ADJUSTMENT 19 10 COMMISSIONING PERIODIC CHECKS 20 11 FREQUENCY OF REGULAR SERVICING 20 12 COLD WATER ISOLATION CWI TEST 21 13...

Страница 3: ...without hole for overhead outlet suitable for A7592AA Wrap over shower shelf A861383AA with hole for overhead outlet suitable for A7594AA 1 2 Wrap over shower shelves 1 1 A7592AA A7594AA Shown above...

Страница 4: ...3 4 150 G 3 4 45 180 4 Basic bath shower mixer dimensions shown with deck mounting legs assembled Dimensions are in millimetres may vary within permitted tolerances 1 3 A7593AA Shown above A7593AA bat...

Страница 5: ...ons are in millimetres may vary within permitted tolerances 1 4 SHOWER PACK A7594AA Note The following two products do not include a shower pack kit A7592AA A7593AA NOTES Where shower mixer products a...

Страница 6: ...upplied without shower kit Right side handle controls flow to a single shower outlet Shower mixer dual pack with overhead Rain shower Hand spray supplied with A7594AA A7594AA Shower valve shown withou...

Страница 7: ...ntrols flow diverts between bath fill shower hand set Note A7593AA is supplied without a shower kit 7 2 2 Deck mount mixer A7593AA NOTE Shower kits have to be carefully assembled during installation c...

Страница 8: ...d as the vertical distance between the bottom of the cold water storage tank which feeds the hot water system and the highest point on the shower spray plate When installing with a shower pump the use...

Страница 9: ...flow regulator A pair of service valves for isolating both water supplies MUST be fitted below the bath to permit future maintenance of this product see sect 23 These should be fitted as close as prac...

Страница 10: ...tted zone of backflow risk for restrained hose which is longer than system design hose not permitted zone of backflow risk for unrestrained hose zone of backflow risk for restrained hose w c spill ove...

Страница 11: ...o the water supply inlets of the mixer in an easily accessible location NOTE service valves are not supplied with thiese products see section 23 Shower Kit The flexible shower hose from the shower kit...

Страница 12: ...m copper supply pipes should be run within the wall cavity Hot supply pipe should be on the left hand side and the cold on the right Ensure that the hot and cold pipes are positioned 150mm apart and a...

Страница 13: ...aging conce aled pipework 10 MIN 20 MAX With the wall brackets in position the supply pipes should be trimmed as shown The pipes should project from the front face of the brackets by bet ween 10 to 20...

Страница 14: ...ing to ensure that the sealing washers filters are inserted between the adaptors and the shower valve inlets Keep the mixer parallel to the wall whilst screwing the captive nuts clockwise by hand Care...

Страница 15: ...ils of the legs into the two holes in the bath Align the legs and gently lower the mixer onto the rim of the bath IMPORTANT make sure the deck seals are still correctly located in the recesses of the...

Страница 16: ...view of overhead shower pack installation A7594AA 1 12 1 2 3 4 5 985 6 6 X X 9 10 2 5 8 7 11 11 12 min 10 Nm Fittings grease Graisse de robinetterie Grasso per rubinetti Kraanvet Grasa de griferia Arm...

Страница 17: ...nter economy flow stop delivering about 50 of the maximum flow rate achievable through this product To obtain greater flow rate press hold the right button rotate this handle further downwards The han...

Страница 18: ...vering about 50 of the maximum flow rate achievable through this product To obtain greater flow rate press hold the right button rotate this handle further downwards The handle will rotate further to...

Страница 19: ...efore sliding the handle off ensure the dot on the handle is inline with the 40 marker on the mixer 4 Slide the handle off the spindle 5 Slide off the plastic bush from the drive spindle 6 Turn on the...

Страница 20: ...low 45 C If there is no significant change to the set outlet temperature 2 C or less change from the original settings and the fail safe shut off is functioning then the valve is working correctly and...

Страница 21: ...clean all filters ensure check valves are working and make sure all isolating valves are fully open Refit the shower handset to the flexible hose upon completion of the test NOTE In order to isolate t...

Страница 22: ...se inline service valves if fitted 2 Fully open the flow or diverter handle to confirm water is switched off Unscrew the shower hose from the underside of the mixer This will permit some of the trappe...

Страница 23: ...y dependent upon the water quality and service life As a minimum we recommend removal both handles thermostatic cartridge flow control or diverter cartridge Cleaning the cartridge strainer screens is...

Страница 24: ...then use a sharp blade to lever the cap out taking care not to damage the chromed surfaces 2 Undo the handle retaining screw using a Phillips screw driver 3 Carefully slide the handle off from the car...

Страница 25: ...idge with a new one Alternatively if the cartridge is functioning correctly clean it thoroughly reuse it 5 When fitting the cartridge into the bore ensure the lug on the cartidge is orientated into th...

Страница 26: ...nsert then Align the dot marker on the handle with the line marker on the stop sleeve Reverse the sequence to refit the handle 18 DIVERTER REPLACEMENT 1 Observe disassembling sequence as detailed in s...

Страница 27: ...the mixer bore screw the cartridge into the mixer body by hand then tighten with a spanner or socket Ideally torque to 16Nm min to 18Nm max 6 Refit the stop ring as illustrated above Align the marked...

Страница 28: ...ral strainers from inside the mixer s inlet bores keep them in a safe location On a regular basis the anti splash nozzle on the bath mixer should be inspected and cleaned if necessary In areas where l...

Страница 29: ...1 371 NU 1 pcs 3 Stopring A 861 373 NU 1 pcs 4 Cartridge G1 2 180 cpl A 861 245 NU 1 Set 5 Nipple G1 2 outside cpl A 861 498 NU 1 Set 6 Non return valve A 861 372 NU 1 Set 7 Shower bracket connect A 8...

Страница 30: ...61 371 NU 1 pcs 3 Stop valve with diverter A 861 375 NU 1 Set 4 Thread ring stopring cpl A 861 376 NU 1 Set 5 Connection nipple cpl A 861 387 NU 1 Set 6 Non return valve A 861 372 NU 1 Set 7 Nipple G1...

Страница 31: ...109 AA 1 pcs 10 Handspray 1F 8l min BC 774 AA 1 pcs 9 10 13 5 9 11 19 12 14 15 16 17 3 4 18 8 2 1 1 6 7 Exposed Thermostatic Bar Shower Mixer with overhead Rain shower Hand spray 11 Shower bar A 861 3...

Страница 32: ...stalled in an easily accessible location Basic valve with isolating only feature is available un der spares code S9005AA 15mm compression fittings at both ends plated finish E960086NU Brass valve with...

Отзывы: