Introduction 

 

Warning

 

To avoid shock or injury, do not perform the verification tests or calibration 

procedures described in this manual unless you are qualified to do so. 

The information provided in this document is for the use of qualified personnel only. 

 

 Caution 

The 61-724 contains parts that can be damaged by static discharge. 

Follow the standard practices for handling static sensitive devices. 

 
 

For additional information about IDEAL INDUSTRIES, INC. and its products, 

and services, visit IDEAL INDUSTRIES, INC. web site at: 

www.idealindustries.com 

 

SAFETY

 

 
Review the following safety precautions to avoid injury and prevent damage to this product or any 
products connected to it. To avoid potential hazards, use the product only as specified. 
 

 

CAUTION. 

These statements identify conditions or practices that could result in damage to the equipment or other 
property. 
 

 

WARNING.  

These statements identify conditions or practices that could result in personal injury or loss of life. 
 

Specific precautions 
 
Use proper Fuse. 

To avoid fire hazard, use only the fuse type and rating specified for this product. 

 

Do not operate without covers.

 To avoid personal injury, do not apply any voltage or current to the 

product without the covers in place. 
 

Electric overload. 

Never apply a voltage to a connector on the product that is outside the range specified 

for that connector. 
 

Avoid electric shock. 

To avoid injury or loss of life, do not connect or disconnect probes or test leads 

while they are connected to a voltage source. 
 

Do not operate in wet/damp conditions. 

To avoid electric shock, do not operate this product in wet or 

damp conditions. 

 
Form number TM61724 

Rev 2 Sept 2006 

Содержание 61-724

Страница 1: ...des the following information Precautions and safety information Specifications Performance test procedure Calibration and calibration adjustment procedure Basic maintenance replacing the battery Form number TM61724 Revision 2 Date September 2006 Form number TM61724 Rev 2 Sept 2006 ...

Страница 2: ...ons 2 General Specification 2 Voltage Specifications 2 Current Specifications 2 Resistance Specifications 2 Frequency Specification 2 Diode Specifications 2 Continuity Specifications 2 Performance Verification 3 Calibration 4 Clamp Jaw Alignment Figures 5 Replacing the Battery 5 Form number TM61724 Rev 2 Sept 2006 ...

Страница 3: ...nly as specified CAUTION These statements identify conditions or practices that could result in damage to the equipment or other property WARNING These statements identify conditions or practices that could result in personal injury or loss of life Specific precautions Use proper Fuse To avoid fire hazard use only the fuse type and rating specified for this product Do not operate without covers To...

Страница 4: ...plicable accuracy specification per C from 0 C to 18 C and 28 C to 50 C 32 F to 64 F and 82 F to 122 F Electrical Specification Accuracy are reading plus number of digits at 23 C 5 C 75 RH Function Setting Ranges Accuracy AC Voltage 200 0 600V at 50 60 Hz 1 2 4digits AC Voltage 200 0 600V at 40 500 Hz 2 0 4 digits DC Voltage 600V 0 5 1 digit AC Current 200 0 1000A at 50 60 Hz 1 75 4 digit AC Curre...

Страница 5: ...he battery measures under 7 5V DC replace the battery before beginning the performance test 3 Input the values listed in Table 1 Table 1 Performance Verification Function Setting Range Input Low Limit High Limit ACV 200 ACV 200 190V AC 50Hz 190V AC 500Hz 187 3 185 8 192 7 194 2 ACV 600 ACV 600 500V AC 60Hz 500V AC 500Hz 490 486 510 514 DCV 600 500V DC 496 503 ACA 200A 100A 50Hz 97 9 102 1 ACA 200A...

Страница 6: ...3 Output 100V DC Adjust R43 until unit display reads 100V De energize source and remove test leads DCA Zero Calibration 1 Remove the Jumper 2 Set the function range to the 200A DC 3 Without any signal applied keeping Jaw away from other devices adjust R54 for a display reading of 0 0 1 digit 4 Replace the Jumper then press the ZERO button adjust R506 for a display reading of 0 0 1 digit DCA Balanc...

Страница 7: ...r 2 Use a Philips head screwdriver to remove the two screws on battery cover 3 Remove battery from compartment and unsnap the battery connector 4 Install new 9V battery NEDA 1604 An alkaline type is recommended 5 Install new battery into compartment using care not to pinch or bind battery leads 6 Reinstall battery cover Figure 2 Form number TM61724 Rev 2 Sept 2006 ...

Отзывы: