3.32 EXTERNAL SYSTEM FILTER CLEANING GUIDE
1. Switch off the boiler (isolate electrical
supply).
2. Close the inlet/outlet valves. Remove
magnet and vent.
3. Remove drain valve cap, open drain valve
and vent.
4.
Open inlet valve slowly and flush out filter
until water runs clear.
5. Close the inlet valve. Close the drain valve.
6. Reinsert the magnet and replace the drain
valve cap.
7.
Open inlet/outlet valves, refill system and
vent.
8. Restart the boiler.
WARNING! Ensure that the magent pocket is
kept dry.
Note:
Remember to re-pressurise system after
cleaning the filter, as loss of pressure will occur.