![Ideal Heating VOGUE MAX SYSTEM 15IE Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/ideal-heating/vogue-max-system-15ie/vogue-max-system-15ie_installation-and-servicing_3722215048.webp)
48
Installation and Servicing
SECTION 3 - SERVICING
3.6 BURNER REMOVAL AND CLEANING
3.7 CLEANING THE CONDENSATE TRAP / SIPHON
1. Refer to Sections 3.2 & 3.3
2. To remove Fan, Burner and Venturi Assembly refer to Section 3.4.
3. Remove the assembly from the heat exchanger.
4. Brush off any deposits with a SOFT brush.
5a. Inspect the burner door sealing gaskets and insulation for signs of
damage. Replace as necessary.
The seal should be checked and replaced if showing any signs of
degradation:
•
Surface imperfections
•
Cracks
•
Discolouration
•
Whitening
Replacement of burner door sealing gasket
5b. Remove the silicon seal from around the burner door location
groove.
6. Re-new the seal and replace in reverse order.
4
5
1. Refer to Sections 3.2 & 3.3.
2. Remove the rubber condensate pipe from the
top of the trap.
3. Rotate the trap clockwise to disengage the
trap and lift clear of the outlet connection.
4. Flush out any debris under running water, and
leave the trap half full of water.
5.
Refit in reverse order making sure the trap is
engaged with the outlet connection.
6. Re-position CH water pressure switch.
2
SER
VICING
Содержание VOGUE MAX SYSTEM 15IE
Страница 4: ...4 Installation and Servicing ...
Страница 6: ...6 Installation and Servicing ...
Страница 69: ...69 SHORT LIST OF PARTS Installation and Servicing ...
Страница 76: ...76 Installation and Servicing NOTES ...
Страница 77: ...77 Installation and Servicing NOTES ...
Страница 78: ...78 Installation and Servicing NOTES ...
Страница 79: ...79 Installation and Servicing NOTES ...