2
Mexico Super FF440 - FF480 -
Installation & Servicing
GENERAL
Key to symbols
GB
= United Kingdom
IE
= Ireland (Countries of destination)
PMS
= Maximum operating pressure of water
C
12
= A room sealed appliance designed for connection via
ducts to a horizontal terminal, which admits fresh air to
the burner and discharges the products of combustion to
the outside through orifices which, in this case, are
concentric. The fan is down stream of the combustion
chamber.
I
2H
= An appliance designed for use on 2nd Family gas,
Group H only.
Note.
Gas consumption is calculated using a calorific value of 38.7
MJ/m
3
(1038 Btu/ft
3
) gross or 34.9 MJ/m
3
(935 Btu/ft
3
) nett. To
obtain the gas consumption at a different calorific value:-
a.
For l/s - divide the gross heat input (kW) by the gross C.V.
of the gas (MJ/m
3
)
b.
For ft
3
/h - divide the gross heat input (Btu/h) by the gross
C.V. of the gas (Btu/ft
3
)
c.
The appliance is preset at the factory to the highest
nominal rating.
*
The value is used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
The test data from which it has been calculated have been certified by a notified body.
Boiler Size
FF440
FF450
FF460
FF470
FF480
Boiler Input
(GROSS)
kW (Btu/h)
14.4 (49 100)
18.1(61 700)
21.7 (74 000)
25.0 (85 300)
28.9 (98 600)
l/s (ft.
3
/h)
0.37 (47.3)
0.47 (59.4)
0.56 (71.3)
0.65 (83.1)
0.75 (95.0)
Boiler Input
(NET)
kW (Btu/h)
13.0 (44 300)
16.3 (55 600)
19.5 (66 500)
22.8 (77 800)
26.0 (88 700)
Boiler Output to Water
kW (Btu/h)
11.7 (40 000)
14.7 (50 000)
17.6 (60 000)
20.5 (70 000)
23.4 (80 000)
Burner Setting Pressure (hot)
mbar (in w.g.)
10.3 (4.4)
11.8 (4.7)
12.2 (4.9)
10.6 (4.3)
13.2 (5.3)
Seasonal Efficiency (SEDBUK)*
Band D
[78.2]%
[78.9]%
[79.0]%
[80.5]%
[79.8]%
Boiler Size
FF440
FF450
FF460
FF470
FF480
Gas Supply Connection
in. BSP
Rc 1/2 (1/2)
Number of Boiler Sections
2
3
3
3
3
Flow and Return Connections
Rc 1 (1" BSP)
MAXIMUM Static Water Head
m (ft.)
30.5 (100)
(3 bar)
MINIMUM Static Water Head
m (ft.)
1.0 (3.3)
Electrical Supply
(Power Consumption)
230 V ~50 Hz (100 W)
Fuse Rating
External: 3 A
Internal: 1A to BS4265
Water Content
litre (gal.)
5.0 (1.1)
7.4 (1.6)
Dry Weight
kg. (lb.)
72 (159)
94 (207)
Maximum Inst Weight
kg. (lb.)
65 (143)
88 (194)
Boiler Size
Height
mm (in.)
850 (33.5)
Width
mm (in.)
440 (17.4)
Depth
mm (in.)
533 (21.0)
Gas Type
Natural 2 H
Gas Supply Pressure
20 mb
Flue duct diameter
mm (in.)
100 (4.0)
Flue duct length (max)
m (ft)
3 (9.8)
Table 2 - Performance Data
CAUTION. To avoid the possibility of injury during the installation, servicing or cleaning of
this appliance, care should be taken when handling edges of sheet steel components.
Table 1 - General Data
200939-1.p65
3/1/2004, 4:33 PM