background image

6

 

User’s

6.  POINTS FOR THE BOILER USER

Note.

  

In line with our current warranty policy we would ask that you check through the following guide to identify any 

problems external to the boiler prior to requesting a service engineer’s visit.  Should the problem be found to be other 

than with the appliance we reserve the right to levy a charge for the visit, or for any pre-arranged visit where access is 

not gained by the engineer.

TROUBLESHOOTING

YES

YES

NO HOT WATER

Check the mains power is turned 

on and ensure mode knob (C) is 

in the summer or winter position

Is water coming out of the hot 

water tap when turned on?

NO CENTRAL HEATING

Check the mains power is turned 

on and ensure mode knob (C) is 

in the winter position

Does the boiler operate and 

provide central heating?

Check the time settings on the 

programmer are as you require 

and adjust if necessary

Check the programmer (internal 

or external to the boiler) is in 

an “ON” position and the room 

thermostat is turned up

NO HOT WATER OR 

CENTRAL HEATING

Check the mains power is turned 

on and ensure mode knob (C) is 

in the winter position

See boiler “Operation Modes” 

and “Fault Codes” section

Does the boiler have a display 

showing on the front control 

panel?

See boiler “Fault Codes” 

section.  If ‘

0

’ is displayed then 

contact Ideal Customer Services 

Helpline if your appliance is 

under warranty or a Gas Safe 

Registered Engineer, in IE a 

Registered Gas Installer (RGII), 

if out of warranty

YES

NO

Contact a Gas Safe Registered 

Engineer or in IE a Registered 

Gas Installer (RGII)

NO

See boiler “Operation Modes” 

and “Fault Codes” section.  If “

0

” 

is displayed then contact a Gas 

Safe Registered Engineer or in 

IE a Registered Gas Installer 

(RGII)

NO

Contact a Gas Safe Registered 

Engineer or in IE a Registered 

Gas Installer (RGII)

Содержание LOGIC CODE COMBI ESP1

Страница 1: ...hat have not been clearly authorised by Ideal Boilers For the very latest copy of literature for specification and maintenance practices visit our website www idealboilers com where you can download the relevant information in PDF format For alternative languages in our User Guides please visit our website www idealboilers com April 2019 UIN 222364 A01 USER GUIDE LOGIC CODE COMBI ESP1 26 33 38 ...

Страница 2: ...o the current ETCI rules for electrical installation It is essential that the instructions in this booklet are strictly followed for safe and economical operation of the boiler ELECTRICITY SUPPLY This appliance must be earthed Supply 230 V 50 Hz The fusing should be 3A IMPORTANT NOTES This appliance must not be operated without the casing correctly fitted and forming an adequate seal If the boiler...

Страница 3: ...ler fails to light after five attempts the fault code will be displayed refer to Fault Code page OPERATION MODES Winter Conditions Central Heating and Domestic Hot Water required Set the mode knob C to winter The boiler will fire and supply heat to the radiators but will give priority to domestic hot water on demand Summer Conditions Domestic Hot Water only required Set the mode knob C to summer S...

Страница 4: ...nob towards the MAX position to meet heating requirements This will depend on the house and radiators used Reducing the room thermostat setting by 1ºC can reduce gas consumption by up to 10 WEATHER COMPENSATION When the Weather Compensation option is fitted to the system then the central heating temperature knob B becomes a method of controlling room temperature Turn the knob clockwise to increase...

Страница 5: ... made before it fully defrosts Warm water can also be poured onto the pipe from a watering can or similar DO NOT use boiling water 3 Caution when using warm water as this may freeze and cause other localised hazards 4 Once the blockage is removed and the condensate can flow freely restart the appliance Refer to To Light the boiler 5 If the appliance fails to ignite call your Gas Safe Registered en...

Страница 6: ...the time settings on the programmer are as you require and adjust if necessary Check the programmer internal or external to the boiler is in an ON position and the room thermostat is turned up NO HOT WATER OR CENTRAL HEATING Check the mains power is turned on and ensure mode knob C is in the winter position See boiler Operation Modes and Fault Codes section Does the boiler have a display showing o...

Страница 7: ...he boiler The boiler is operating in central heating mode The boiler is operating in domestic hot water mode The boiler is operating in frost protection 7 NORMAL OPERATION DISPLAY CODES The boiler mode knob C is in the off position rotate fully clockwise for hot water and central heating operation FP 54 54 00 54 54 o C o C o C o C FOR ANY QUERIES PLEASE RING THE IDEAL CONSUMER HELPLINE 01482 49866...

Страница 8: ...arranty or alternatively a Gas Safe Registered Engineer if outside of the warranty period In IE contact a Registered Gas Installer RGII 1 Check condensate pipe for blockages refer to Section 4 2 Check other gas appliances in the house are working to confirm a supply is present in the property 3 If other appliances do not work or there are no other appliances check the gas supply is on at the meter...

Отзывы: