Classic
LXFF, FF
-
Installation
5
INTRODUCTION
The Classic FF230-2 100
(standard) and the
Classic LX FF 230-
280
(deluxe casing) is a range of automatically fully controlled,
wall mounted, balanced flue, fanned gas boilers.
The heat exchanger is cast iron. The boiler casing is of white
enamelled mild steel.
FF 230-2 100 (Standard Model)
The boiler casing has a removable controls pod containing a drop-
down door. The boiler thermostat is located behind the drop- down
door.
FF LX 230-280 (Deluxe Model LX)
The boiler casing is fitted with a glass fascia. The glass fascia can
be lifted up to gain access to the boiler thermostat.
All details for the deluxe casing model are the same as the
standard model unless otherwise stated.
Note.
These boilers cannot be used on systems which include
gravity circulation.
If gravity circulation is required the
Classic RS
range of boilers is suitable.
See Frame 1 for details of the correct boiler tappings to use.
The boilers are supplied with a standard flue kit suitable for rear or
side outlet applications from 114 mm (4
1/2
") to 600 mm
(23
1/2
").
The boilers are suitable for connection to the following open
vented or sealed systems:
z
Fully pumped CH and indirect DHW
z
Pumped heating only.
z
Pumped indirect DHW only.
OPTIONAL EXTRA KITS
Downward Piping Kit.
Programmer Kit.
Vertex Flue Kit*
- for vertical flue connection
Roof Flue Kit*
90°
Flue Elbow Kit
*
Sealed System Unit -
this fits on top of the appliance.
Suitable for standard boiler only.
Extension ducts
*
-
up to 3m (118").
Turret Outlet Kit.
*
*
not available for FF2 100
The installation of the boiler MUST also be in accordance with the
latest I.E.E (BS.7671) Wiring Regulations, local building
regulations, bylaws of the local water authority, the Building
Regulations and Building Standards (Scotland) and any relevant
requirements of the local authority. Detailed recommendations
are contained in the following British Standard Codes of Practice:
BS.6891
Low pressure installation pipes.
BS.6798
Installation of gas fired hot water boilers of rated input
not exceeding 60 kW.
BS.5449
Forced circulation hot water systems.
BS.5546
Installation of gas hot water supplies for domestic
purposes (2nd Family Gases).
BS.7593
Treatment of water in domestic hot water central
heating systems.
BS.5440.1
Flues for gas appliances of rated input not exceeding
60 kW.
BS.5440.2
Ventilation for gas appliances of rated input not
exceeding 60 kW.
Health & Safety Document No. 635
The Electricity at Work Regulations, 1989.
Manufacturer’s notes must NOT be taken in any way as overriding
statutory obligations.
IMPORTANT.
These appliances are certificated by the British
Standards Institution for safety and performance. It is, therefore,
important that no external control devices, e.g. flue dampers,
economisers etc., are directly connected to these appliances -
unless covered by these Installation and Servicing instructions or
otherwise recommended by
Caradon Plumbing Limited
in writing.
If in doubt please enquire.
Any direct reconnection of a control device not approved by
Caradon Plumbing Limited
could invalidate the BSI Certification
and the normal appliance warranty. It could also infringe the Gas
Safety Regulations and the above regulations.
LOCATION OF BOILER
The boiler must be installed on a flat and vertical wall, capable of
adequately supporting the weight of the boiler and any ancillary
equipment.
The boiler may be fitted on a combustible wall and insulation
between the wall and the boiler is not necessary - unless required
by the local authority.
The boiler must not be fitted outside.
Timber Framed Buildings
If the boiler is to be fitted in a timber framed building it should be
fitted in accordance with the Institute of Gas Engineering document
IGE/UP/7:1998.
Bathrooms
The boiler may be installed in any room or internal space, although
particular attention is drawn to the requirements of the current I.E.E.
(BS.7671) Wiring Regulations and, in Scotland, the electrical
provisions of the building regulations applicable in Scotland with
respect to the installation of the boiler in a room or internal space
containing a bath or shower.
continued on page 7
GENERAL
NOTE TO THE INSTALLER: LEAVE THESE
INSTRUCTIONS ADJACENT TO THE GAS METER.
ALSO COMPLETE THE BENCHMARK LOG BOOK
AND GIVE THIS TO THE CUSTOMER.
GAS SAFETY (INSTALLATION AND USE) Regulations
1994, amendments 1996 or rules in force.
It is law that
all
gas appliances are installed by a CORGI registered
installer (identified by
) in accordance with the above regulations.
Failure to install appliances correctly could lead to prosecution. It
is in your own interest, and that of safety, to ensure the law is
complied with.