2

Classic FF - 

Users

To light the boiler.

Refer to Frame 1

If a programmer is fitted, refer to separate instructions for the
programmer before continuing.

1. CHECK THAT THE ELECTRICITY SUPPLY TO THE BOILER

IS OFF.

2. Open the controls access door by hinging downwards.

3. Ensure that the gas inlet cock (D) is OPEN.

4. Press the overheat reset button (E), located as shown in

Frame 1.

5. Ensure that the mains on/off switch (C) is in the OFF position.

6. Switch ON the electricity supply to the boiler. Check that all

external controls, e.g. room thermostat etc., are ON.

7. Turn the boiler thermostat knob (B) to position 6 and the

mains on/off switch (C) to ON.  After about 15 seconds the
boiler will light automatically - this can be viewed through the
sight glass (A).
Set the boiler thermostat to the desired position.

8. Close the controls access door.

Classic FF  (Natural Gas Models Only)

Introduction

It is essential that the instructions in this booklet are
strictly followed, for safe and economic operation of
the boiler.

Current Gas Safety (Installation &
Use) Regulations or rules in force.

In your own interest, and that of safety, it is the law that this
boiler must be installed by a CORGI registered installer or in IE
a competent person, in accordance with the above regulations.

Electricity Supply

This appliance must be efficiently earthed.

Supply: 230 V ~ 50 Hz. 

The fusing should be 3A.

Connection must be made in a way that allows complete
isolation of the electrical supply such as a double pole switch
having a 3mm (1/8") contact separation in both poles, or a
plug and socket, serving only the boiler and system controls.
The means of isolation must be accessible to the user after
installation.

Important notes

a.

This appliance must not be operated without the casing
correctly fitted and forming an adequate seal.

b.

If the boiler is installed in a compartment then the compartment
MUST NOT be used for storage purposes.

c.

The ventilation provided for the boiler during installation MUST
NOT be blocked, and a check should be made periodically
that the ventilation areas are free from any obstruction.

d.

If it is known or suspected that a fault exists on the boiler then
it MUST NOT be used until the fault has been corrected by a
CORGI registered installer or in IE a competent person.

e.

Flammable materials must not be placed in close proximity
to the appliance.  Materials giving off flammable vapours must
not be stored in the same room as the appliance.

f.

Where the boiler is fitted with a Vertex flue system with a
draught diverter in the loft the loft space MUST NOT be used
as a dwelling area.

g. Under NO circumstances should any of the sealed

components on this appliance be used incorrectly or tampered
with.

Minimum clearances

A clearance of 533mm (21") MUST be available at the front of the
boiler for servicing.

The minimum clearances given below MUST be complied with
in order to maintain the safe running of the boiler .

Above the boiler

100 mm

(4")

At each side of the boiler

5 mm

(

1/4

")

Underneath the boiler

100 mm

(4")

In front of the boiler

75 mm

(3")

Classic FF 330 ......................... G.C. No. 41 391 54
Classic FF 340 ......................... G.C. No. 41 391 95
Classic FF 350 ......................... G.C. No. 41 391 96
Classic FF 360 ......................... G.C. No. 41 391 97
Classic FF 370 ......................... G.C. No. 41 391 98
Classic FF 380 ......................... G.C. No. 41 391 99
Classic FF 3 100 ...................... G.C. No. 41 392 01

Classic FF 340 LF .................... G.C. No. 41 392 90
Classic FF 350 LF .................... G.C. No. 41 392 91
Classic FF 360 LF .................... G.C. No. 41 392 92

CAUTION.  To avoid the possibility of injury during the installation, servicing or cleaning of
this appliance care should be taken when handling edges of sheet steel components