background image

2

 

IDEAL CLASSIC

 - 

User’s

THE BENCHMARK SERVICE INTERVAL RECORD MUST BE COMPLETED AFTER EACH SERVICE

Ideal

 is a member of the Benchmark scheme and fully supports the aims of the programme.  

Benchmark has been introduced to improve the standards of installation and commissioning of 

central heating systems in the UK and to encourage the regular servicing of all central heating 

systems to ensure safety and efficiency.

All Gas Safe Register installers carry a Gas Safe Register ID card, and have a registration number.  Both should be recorded in the

Benchmark Commissioning Checklist.  You can check your installer by calling Gas Safe Register direct on 0800 4085500.

1. INTRODUCTION

The 

Ideal Classic 

is a combination boiler providing both central 

heating and instantaneous domestic hot water.  Featuring full 

sequence automatic ignition and fan assisted combustion.

Due to the high efficiency of the boiler, condensate is produced from 

the flue gases and this is drained to a suitable disposal point through 

a plastic waste pipe at the base of the boiler.  A condensate ‘plume’ 

will also be visible at the flue terminal.

SAFETY

Current Gas Safety (Installation & Use) Regulations or 

rules in force.

In your own interest, and that of safety, it is the law that this 

boiler must be installed by a Gas Safe Registered Engineer, in 

accordance with the above regulations.
In IE, the installation must be carried out by a Registered Gas Installer 

(RGII) and installed in accordance with the current edition of I.S. 813 

“Domestic Gas Installations”, the current Building Regulations and 

reference should be made to the current ETCI rules for electrical 

installation.

It is essential that the instructions in this booklet are strictly 

followed, for safe and economical operation of the boiler.

ELECTRICITY SUPPLY

This appliance must be earthed.

Supply: 230 V ~ 50 Hz. The fusing should be 3A.

IMPORTANT NOTES

•  This appliance must not be operated without the casing 

correctly fitted and forming an adequate seal.

•  If the boiler is installed in a compartment then the compartment 

MUST NOT be used for storage purposes.

•  If it is known or suspected that a fault exists on the boiler then 

it MUST NOT BE USED until the fault has been corrected by 

a Gas Safe Registered Engineer or in IE a Registered Gas 

Installer (RGII).

 

Under NO circumstances should any of the sealed components 

on this appliance be used incorrectly or tampered with.

• 

T

his appliance can be used by children 8 years and 

above.

  

A

lso persons with reduced physical, sensory or 

mental capabilities, or lack of experience and knowledge, 

provided they have been given supervision or instruction 

concerning use of the appliance in a safe way and 

understand the hazards involved.  Children shall not play 

with the appliance.

  

C

leaning and user maintenance 

shall not be made by children without supervision.

CONTENTS

 

1.  Introduction

 

 .............................................................. 2

     Safety ......................................................................... 2
     Electricity Supply ........................................................ 2
     Important Notes .......................................................... 2

2.  Boiler Operation ....................................................... 3

     Controls Diagram........................................................ 3
     To Start the Boiler ....................................................... 3
     Operation Modes ........................................................ 3
     Preheat Domestic Hot Water ...................................... 3
     Control of Water Temperature .................................... 3

     Efficient Heating System Operation

............................ 4

     Weather Compensation .............................................. 4
     Boiler Frost Protection ................................................ 4
     Boiler Reset ................................................................ 4
     Mains Power Off ......................................................... 4

3.  System Water Pressure ........................................... 4

4.  Condensate Drain

 ..................................................... 4

5.  General Information ................................................. 5

     Boiler Pump ................................................................ 5

    

     Minimum Clearances .................................................. 5
     Escape of Gas ............................................................ 5
     Cleaning ..................................................................... 5
     Maintenance ............................................................... 5

6.  Mechanical 24 Hour Timer

 ....................................... 5

7.  Points for the Boiler User

 ........................................ 6

     Troubleshooting .......................................................... 6

8.  Normal Operation Display Codes

 ........................... 7

9.  Fault Codes

 ............................................................... 8

Содержание CLASSIC 24

Страница 1: ...nd performance speci cation that we require Do not use reconditioned or copy parts that have not been clearly authorised by Ideal For the very latest copy of literature for speci cation and maintenanc...

Страница 2: ...lectrical installation It is essential that the instructions in this booklet are strictly followed for safe and economical operation of the boiler ELECTRICITY SUPPLY This appliance must be earthed Sup...

Страница 3: ...he external controls to OFF The domestic hot water preheat will operate if preheat is enabled shown by indicator light F Boiler Off Set the mode knob A to off The boiler mains power supply must be lef...

Страница 4: ...o ignite call your Gas Safe Registered engineer Preventative solutions During cold weather set the central heating temperature knob C to maximum Must return to original setting once cold spell is over...

Страница 5: ...t once a year by a Gas Safe Registered Engineer or in IE a Registered Gas Installer RGII 6 MECHANICAL 24 HOUR TIMER 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 13 1 4 1 5 1 6 1 7 1 8 19 2 0 2 1 2 2 23 24 ON PERIOD...

Страница 6: ...ovide central heating Check the time settings on the timer are as you require and adjust if necessary Check the timer is in an ON position and the room thermostat is turned up NO HOT WATER OR CENTRAL...

Страница 7: ...for hot water but the appliance has reached the desired temperature set on the boiler The boiler is operating in central heating mode The boiler is operating in pre heat mode The boiler is operating i...

Страница 8: ...on at the meter and or pre payment meter has credit If the boiler fails to operate then please contact Ideal Boilers if under warranty or alternatively a Gas Safe Registered Engineer if outside of th...

Отзывы: