CALEO HOT/NEUTRAL
Possibility of disconnection from the power grid
Ensure that the appliance cladding and the counters are prepared in accordance with the technical specifications. The size of the
installation opening for the respective model can be found in the current product catalogue under the “Technical Data” for the pro
-
duct, or in the production drawing. Please note that the dimensions of the bottom tray (see Chapter 2.1) can expand due to the heat
in the unit. The bottom tray must not lie on the installation opening or cladding. Protect the surfaces of the unit and the base against
any damage during the installation.
If a plug connection is used for the mains connection, the power outlet must be easily accessible to be able to disconnect the unit
from the power grid if need be (cleaning, maintenance work). If direct wiring is used, a means of disconnecting the unit from the
power grid must be created.
The unit must be leveled after assembling.
NOTE
Connecting the units in the base:
All the units must be connected in the base. A blind rivet nut is pre-installed in the base on each side of the unit for this. Connect the
two units that are beside each other by means of a screw (M8) in the designated blind rivet nuts. Check the hold of the connection.
The holes for the connecting screws must overlap.
Step 4:
Place the connecting screws in the two holes and tighten them. Check the hold of the connection.
Step 5:
Mount the ventilation duct cover on the left and right, as well as the ventilation duct. Check the hold of the
parts mentioned. Ensure that the exhaust air duct is not covered or dirtied. Air circulation must be ensured so that the
unit functions properly.