Subject to technical changes | Valid from January 2021
27
CALEO HOT/NEUTRAL
2.3.1. Electrical information
Danger from electrical voltage on live components
When disposing of damaged parts/components, wear protective gloves. Dispose of damaged parts/components properly
and in an environment-friendly way. Observe the country-specific laws
DANGER
Connecting the unit
Units for a rated voltage of 230 V, 50/60 Hz (single-phase) are supplied with a power plug as standard. Units for 400 V, 50/60 Hz
(three-phase) must be connected to the power grid by a trained specialist.
The following conditions must be met for a proper connection:
•
Permanent availability of 16 A of current per phase must be ensured.
•
Any deficiencies in the power supply must be resolved before connecting the unit.
The manufacturer of the unit is not responsible for damage caused by improper connection.
The following electrical connections must be ensured by the operator:
Units with 230V, 50/60 Hz (single-phase): 1x 16A
Units with 400 V, 50/60 Hz (three-phase); 3x 16 A
For units with 400 V electric connection, a three-pole main switch must be provided on site!
Not included in the scope of delivery.
NOTE
Danger from electrical voltage on live components
The mains voltage and frequency must match the values stated on the rating plate. It is not permitted to connect the unit
to any other voltage, type of current or frequency. The relevant local legal safety regulations must be observed. If the grid
connection is damaged, it must be removed and replaced by an authorised specialist.
DANGER