If the drain joint doesn’t come with a rubber seal
(see
FIG. 4.4 - B
), do the following:
• Insert the drain joint into the hole in the base pan of the
unit. The drain joint will click in place.
• Connect a drain hose extension (not included) to the drain
joint to redirect water from the unit during heating mode.
IN COLD CLIMATES
In cold climates, make sure that the drain hose is as vertical
as possible to ensure swift water drainage. If water drains
too slowly, it can freeze in the hose and flood the unit.
STEP 3: ANCHOR OUTDOOR UNIT
The outdoor unit can be anchored to the ground or to a wall-mounted bracket.
UNIT MOUNTING DIMENSIONS
The following is a list of different outdoor unit sizes and the distance between their mounting feet.
Prepare the installation base of the unit according to the dimensions below.
FIG. 4.4
WARNING
W
A
B
D
Air inlet
Air outlet
Air inlet
Outdoor Unit Dimensions (mm/in)
W x H x D
Mounting Dimensions
Distance A (mm/in)
Distance B (mm/in)
681x434x285 (26.8”x17”x11.2”)
460 (18.10”)
292 (11.49”)
700x550x270 (27.5”x21.6”x10.62”)
450 (17.7”)
260 (10.24”)
780x540x250 (30.7”x21.25”x9.85”)
549 (21.6”)
276 (10.85”)
845x700x320 (33.25”x27.5”x12.6”)
560 (22”)
335 (13.2”)
810x558x310 (31.9”x22”x12.2”)
549 (21.6”)
325 (12.8”)
900x860x315 (35.4”x33.85”x12.4”)
590 (23.2”)
333 (13.1”)
945x810x395 (37.2”x31.9”x15.55”)
640 (25.2”)
405 (15.95”)
946x810x420 (37.21”x31.9”x16.53”)
673 (26.5”)
403 (15.87”)
946x810x410 (37.21”x31.9”x16.14”)
673 (26.5”)
403 (15.87”)
845x702x363 (33.25”x27.63”x14.29”)
540 (21.26”)
350 (13.8”)
700x550x275 (27.5”x21.6”x10.82”)
450 (17.7”)
260 (10.24”)
770x555x300 (30.3”x21.85”x11.81”)
487 (19.2”)
298 (11.73”)
800x554x333 (31.5”x21.8”x13.1”)
514 (20.24”)
340 (13.39”)
FIG. 4.5