STEP 8: MOUNT INDOOR UNIT

If you installed new connective piping to the outdoor unit,  
do the following:
•  If you have already passed the refrigerant piping through 
  the hole in the wall.
•  Otherwise, double-check that the ends of the refrigerant 
  pipes are sealed to prevent dirt or foreign materials from 
  entering the pipes.
•  Slowly pass the wrapped bundle of refrigerant pipes, drain 
  hose, and signal wire through the hole in the wall.
•  Hook the top of the indoor unit on the upper hook of the 
  mounting plate (Refer to 

FIG. 3.11

).

•  Check that unit is hooked firmly on mounting by applying 
  slight pressure to the left and right-hand sides of the unit. 
  The unit should not jiggle or shift.
•  Using even pressure, push down on the bottom half of the 
  unit. Keep pushing down until the unit snaps onto the hooks 
  along the bottom of the mounting plate.
•  Again, check that the unit is firmly mounted by applying 
  slight pressure to the left and the right-hand sides of the unit.

If refrigerant piping is already embedded in the wall,  
do the following:
•  Hook the top of the indoor unit on the upper hook of the 
  mounting plate.
•  Use a bracket or wedge to prop up the unit, giving you 
  enough room to connect the refrigerant piping, signal 
  cable, and drain hose (Refer to 

FIG. 3.11

 for an example).

•  Connect drain hose and refrigerant piping
  (refer to 

Refrigerant Piping Connection

 

  section of this manual for instructions).
•  Keep pipe connection point exposed to 
  perform the leak test (refer to 

Electrical 

 Checks

 and Leak Checks section of this 

 manual).
•  After the leak test, wrap the connection 
  point with insulation tape.
•  Remove the bracket or wedge that is 
  propping up the unit.
•  Using even pressure, push down on the 
  bottom half of the unit. Keep pushing 
  down until the unit snaps onto the hooks 
  along the bottom of the mounting plate.

UNIT IS ADJUSTABLE

Keep in mind that the hooks on the mounting plate are smaller than the holes on the back of the unit. If you find 
that you don’t have ample room to connect embedded pipes to the indoor unit, the unit can be adjusted left or 
right by about 30-50mm/1.25-1.95", depending on the model. (See 

FIG. 3.12

).

Move to left or right

30-50mm

/1.2-1.95”

30-50mm

/1.2-1.95”

FIG. 3.12

FIG. 3.11

bq

Содержание PRO

Страница 1: ...NER INSTALLATION MANUAL This manual only describes the installation of the indoor unit When installing the outdoor unit refer to the installation manual of outdoor unit 700807 700808 PRO MINI SPLIT I...

Страница 2: ...ur purchase of Ideal Air s Pro Mini Split indoor wall mount unit We re proud to offer this product and believe it s the very best in its class 2 SAFETY PRECAUTIONS 3 ACCESSORIES 5 INSTALLATION SUMMARY...

Страница 3: ...n cause water leakage electrical shock fire and can cause the unit to fail Install the unit in a firm location that can support the unit s weight If the chosen location cannot support the unit s weigh...

Страница 4: ...UTION NOTE ABOUT FLUORINATED GASES This air conditioning unit contains fluorinated gases For specific information on the type of gas and the amount please refer to the relevant label on the unit itsel...

Страница 5: ...nd fire or equipment failure Name Shape Quantity 1 1 1 Clip anchor Mounting plate fixing screw ST3 9 X 25 Remote control Fixing screw for remote control holder ST2 9 x 10 Remote control holder Dry bat...

Страница 6: ...tion Page 9 And Drill Wall Hole Page 10 1 Attach Mounting Plate Page 10 2 Prepare Refrigerant Piping Page 12 4 3b 12cm 4 75 2 3m 90 55 12cm 4 75 15cm 5 9 Determine Wall Hole Position Page 10 3a INSTAL...

Страница 7: ...7 Mount Indoor Unit Page 16 STEP 8 Wrap Piping and Cable Page 15 1 2 3 Connect Drain Hose Page 13 Connect Signal Cable Page 14 5 6 7 8...

Страница 8: ...nt Panel Outdoor Unit Power Cable Some Units Remote Holder Remote Control Some Units UNIT PARTS NOTE ON ILLUSTRATIONS Illustrations in this manual are for explanatory purposes The actual shape of your...

Страница 9: ...t the weight of the unit A location at least 1m 40 from all other electrical devices e g TV radio computer DO NOT INSTALL UNIT IN THE FOLLOWING LOCATIONS Near any source of heat steam or combustible g...

Страница 10: ...2 5 core drill drill a hole in the wall Make sure that the hole is drilled at a slight downward angle so that the outdoor end of the hole is lower than the indoor end by about 5mm 7mm 0 2 0 275 This...

Страница 11: ...m 1 55 Right rear wall hole 65mm 2 5 Model C 965mm 38 138mm 5 45 34mm 1 35 517 4mm 20 37 Indoor unit outline Left rear wall hole 65mm 2 5 219mm 8 6 553mm 21 77 300mm 11 8in 335mm 13 2 Right rear wall...

Страница 12: ...ILL AFFECT THE UNIT S PERFORMANCE Use scissors to cut down the length of the insulating sleeve to reveal about 15cm 6 of the refrigerant piping This serves two purposes a To facilitate the Refrigerant...

Страница 13: ...a small amount of water into the drain pan to make sure that water flows from the unit smoothly PLUG THE UNUSED DRAIN HOLE To prevent unwanted leaks you must plug the unused drain hole with the rubber...

Страница 14: ...it to an individual branch circuit outlet DO NOT connect another appliance to that outlet Make sure to properly ground the air conditioner Every wire must be firmly connected Loose wiring can cause th...

Страница 15: ...he wire cover on the front of the unit and the plastic panel on the back STEP 7 WRAP PIPING AND CABLES Before passing the piping drain hose and the signal cable through the wall hole you must bundle t...

Страница 16: ...dded in the wall do the following Hook the top of the indoor unit on the upper hook of the mounting plate Use a bracket or wedge to prop up the unit giving you enough room to connect the refrigerant p...

Страница 17: ...e to the direction of the wind If needed build a barrier in front of the unit to protect it from extremely heavy winds See FIG 4 2 and FIG 4 3 above INSTALLATION INSTRUCTIONS OUTDOOR UNIT IF THE UNIT...

Страница 18: ...etween their mounting feet Prepare the installation base of the unit according to the dimensions below FIG 4 4 WARNING W A B D Air inlet Air outlet Air inlet Outdoor Unit Dimensions mm in W x H x D Mo...

Страница 19: ...1 5 times the maximum current of the unit If connecting power to fixed wiring a switch or circuit breaker that disconnects all poles and has a contact separation of at least 3mm 125 must be incorpora...

Страница 20: ...and place it to the side Match the wire colors labels with the labels on the terminal block and firmly screw the u lug of each wire to its corresponding terminal After checking to make sure every conn...

Страница 21: ...of 5m 16 5 Refer to the table below for specifications on the maximum length and drop height of piping MAXIMUM LENGTH AND DROP HEIGHT OF REFRIGERANT PIPING PER UNIT MODEL DO NOT DEFORM PIPE WHILE CUTT...

Страница 22: ...or cracks and even flaring STEP 4 CONNECT PIPES When connecting refrigerant pipes be careful not to use excessive torque or to deform the piping in any way You should first connect the low pressure pi...

Страница 23: ...quirements shown in the table above WARNING TORQUE REQUIREMENTS Outer Diameter of Pipe mm Tightening Torque N cm Add Tightening Torque N m 6 35 0 25 1 500 11lb ft 1 600 11 8lb ft 9 52 0 375 2 500 18 4...

Страница 24: ...Using hexagonal wrench fully open both the high pressure and low pressure valves Tighten valve caps on all three valves service port high pressure low pressure by hand You may tighten it further usin...

Страница 25: ...CODES AND MUST BE INSTALLED BY A LICENSED ELECTRICIAN GAS LEAK CHECKS There are two different methods to check for gas leaks SOAP AND WATER METHOD Using a soft brush apply soapy water or liquid deter...

Страница 26: ...ent temperature is below 17 C In this instance you can use the MANUAL CONTROL button to test the COOL function Lift the front panel of the indoor unit and raise it until it clicks in place The MANUAL...

Страница 27: ...greater the number rating the more efficient the heating A 10 HSPF for example is a very good rating Humidifier Humidifiers use water to put humidity in the growing space Many plants we grow indoors a...

Страница 28: ...answers to most common questions and a complete technical support library please visit www ideal air com All design and specifications herein are subject to change without notice for product improveme...

Отзывы: