background image

8

9

Installation

Installation

Vertical

Window 

Shown with

optional

Window

Slider Kit

and Duct

Adapters

installed.

A

Fig. 2

Fig. 3

Fig. 4

Window Slider Kit Installation

Installing the Window Slider Kit in a Vertical, Double-Hung Sash Window

Locking Bolt

Adhesive

Foam Seal

Adhesive

Foam Seals

Adhesive

Foam Seal

Window

Slider Kit

Adhesive Foam Seal

Slider

A

TYPE I
TYPE II

2.22 to 4.04 ft. (67.5 – 123 cm)
1.84 to 3.22 ft. (56.2 – 98.2 cm)

The air conditioner should be placed on a firm 

surface to minimize noise and vibration. For safe 

and secure operation, place the unit on a smooth, 

level floor strong enough to support it.

  

The unit has casters to aid in moving but it should 

only be rolled across smooth, flat surfaces. Use 

caution when rolling on carpeted surfaces. Do not 

attempt to roll the unit over objects.
The unit must be placed within reach of a properly 

rated and grounded socket.

 

Allow at least 12” (30cm) of space from the wall for 

efficient air conditioning. (Fig. 1)

12” (30cm)

12” (30cm)

Fig. 1

Fig. 5

Fig. 6

Fig. 7

Fig. 8

Your optional, 2-piece Window Slider Kit has been 

designed to fit most standard vertical and horizontal 

windows (Fig. 2 & 3). However, it may be necessary 

to cut the Slider shorter to fit windows that are less 

than 2.22 ft. (67.5 cm) wide (Type I) or less than 1.84 

ft. (56.2 cm) wide (Type II). See Fig. 4 below for 

minimum and maximum window openings (A) that the 

Window Slider Kit will fit 

without

 modification.

1. Cut 1 piece of Adhesive Foam Seal to the proper

    length, raise the window sash and attach the foam

    to the window stool (Fig. 5)

2. Adjust the length of the Window Slider Kit to the

    width of the window. Shorten the Slider if the width

    of the window is less than 26.5” (Type I) or 22.1”

    (Type II). Place the Window Slider kit on top of the

    Adhesive Foam Seal (Fig. 6)

3. Cut another piece of Adhesive Foam Seal to the

    proper length and attach it to the top of the Window

    Slider Kit. Close the window sash securely against

    the Top of the Window Slider Kit (Fig. 7).

4. Cut a third piece of Adhesive Foam Seal to the

    appropriate length to seal any gap between the

    top window sash and outer window sash (Fig. 8).

Air Conditioner Placement

Horizontal

Window 

A

Содержание Portable Air Conditioner

Страница 1: ...are subject to change without notice for product improvement Contact Ideal Air for details updates and other information For warranty claims contact the Customer Care Center 1 866 646 4332 Contact Ideal Air Support directly at support ideal air com or call 1 877 9 IDEAL 1 Product defect Not working properly DO NOT return this product to the store where you purchased it For answers to the most comm...

Страница 2: ... free of charge SAFETY PRECAUTIONS 2 3 PARTS IDENTIFICATION 4 5 CONTROL PANEL Overview and Operation 6 7 INSTALLATION Unit Placement 8 Window Slider Kit Installation 8 Installation in a Vertical Window 9 Installation in a Horizontal Window 10 Connecting Intake and Exhaust Hoses 11 Vent Control Feature 11 Water Drainage 11 CARE MAINTENANCE 12 TROUBLESHOOTING TIPS 13 WARRANTY 14 NOTE Rating data on ...

Страница 3: ...humidify HEAT heat pump HEAT element 62ºF 17ºC to 95ºF 35ºC 55ºF 13ºC to 95ºF 35ºC 41ºF 5ºC to 88ºF 30ºC 88ºF 30ºC WARNING For your safety How to operate the current detection device Do not store or use gasoline or other flammable liquids or vapors in the vicinity of this or any other appliance Avoid fire hazard or electric shock Do not use an extension cord or an adapter plug Do not remove any pr...

Страница 4: ...rtical Louver Blade Horizontal Louver Blade Carrying Handle both sides Caster 1 2 3 5 4 6 10 1 2 3 4 5 6 CLOSE OPEN 7 8 9 13 11 12 7 8 9 10 11 12 Air Filter Intake Port Drain Outlet Vent Control Exhaust Port Power Cord Caddy Bottom Drain Outlet 13 ACCESSORIES INCLUDED FRONT REAR To order Optional Accessories visit www Ideal Air com or call 1 877 9 IDEAL 1 OPTIONAL ACCESSORIES TE MP AU TO CO OL DR ...

Страница 5: ...urself with the Control Panel Remote Control and all of their functions see Remote Control Instructions packaged with the remote Timer on off indicator lights Signal receptor not applicable to units without remote control 1 2 3 4 5 6 Mode Indicator Lights Fan speed indicator lights Power indicator light 7 TEMP ADJUST TIMER ON TIMER OFF MODE FAN SPEED ION POWER COOL DRY FAN MED HI LO F C 8 HEAT Ope...

Страница 6: ...cm 12 30cm Fig 1 Fig 5 Fig 6 Fig 7 Fig 8 Your optional 2 piece Window Slider Kit has been designed to fit most standard vertical and horizontal windows Fig 2 3 However it may be necessary to cut the Slider shorter to fit windows that are less than 2 22 ft 67 5 cm wide Type I or less than 1 84 ft 56 2 cm wide Type II See Fig 4 below for minimum and maximum window openings A that the Window Slider K...

Страница 7: ... EXHAUST HOSE when unit is in COOL HEAT heat pump or AUTO mode DISCONNECT EXHAUST HOSE when unit is in FAN DEHUMIDIFY or HEAT element mode DRY dehumidify Mode 1 Remove drain plug from the back of the unit Fig 16 2 Connect standard 5 8 garden hose not included 3 Route hose to secure drain Make sure there are no kinks and the hose drains freely NOTE For double duct design water drainage is not requi...

Страница 8: ... from the remote and store them in a separate plastic bag 4 Remove the air filter clean and reintall it 5 Disconnect exhaust hose store it securely and cover the window openings NOTE Check to make sure tray drain plug is present when removing the unit from storage and returning it to use Unit doesn t start when Power ON is pressed Unit not cooling enough Unit shutting off during HEAT mode Noise or...

Страница 9: ...14 Warranty Notes ...