NOTE: The Control Panel on the unit you purchased may be slightly different than shown.
Setting the Timer
(Timer must be set with unit Power OFF)
ERROR/PROTECTION CODES
Control Panel
Control Panel
1
5
6
7
8
2
3
Power ON/OFF
Fan Speed
Press to select fan speed in 3 steps:
HI, MED and LOW. Note: when all
fan speed indicators are off, fan speed
is set to AUTO which is only selected
via the remote control.
Fan Speed Options:
• COOL (3 speeds): HI-MED-LO
• DRY (1 speed): LO
• FAN (3 speeds): HI-MED-LO
• HEAT (3 speeds): HI-MED-LO
Temp. Adjust
Adjust temperature up or down in
in 2
˚F (1˚C) increments ranging from
62
˚F (17˚C) to 88˚F (30˚C). Also used
to adjust timer settings.
NOTE: To set display between
˚
F or
˚
C, press and hold up and
down Temp. Adjust buttons together
for 3 seconds.
Timer OFF
Press to initiate or cancel the Auto Stop
program. Use to set values.
Timer ON
Press to initiate or cancel the Auto Start
program. Use to set values.
ION Indicator (optional)
To turn Ionizer ON or OFF, press and hold
the “Fan Speed” button for 3 seconds.
For units with Ionizer installed only.
MODE Select
Selects appropriate operating mode. Each
time you press the button, a different mode
is selected from COOL, DRY, FAN and HEAT.
The corresponding indicator light will come
on with mode selected.
LED Display
Displays set temperature in
˚F or ˚C.
Also displays timer settings.
4
1. With the unit Power OFF, press the “Timer On” button to activate the Auto Start program.
2. When the Auto Start program is initiated, press the buttons to adjust times up or down in increments of
0.5 hour up to 10 hours – then at 1 hour increments up to 24 hours.
3. Repeat steps #1 and #2 to set the Auto Stop program.
4. When Auto Start and Auto Stop times are set within the same program sequence, the “Timer On” and “Timer
Off” indicator lights illuminate to indicate that both ON and OFF times are now programmed.
E1 – Evaporator temperature sensor error. Unplug unit and plug back in. If error repeats, call for service.
E2 – Room temperature sensor error. Unplug unit and plug back in. If error repeats, call for service.
P1 – Bottom tray is full of water. Remove drain plug and remove collected water.
Before operating your air conditioner, thoroughly familiarize yourself with the Control Panel, Remote Control and
all of their functions (see Remote Control Instructions packaged with the remote).
Timer on/off indicator lights
Signal receptor
(not applicable to units
without remote control)
1
2
3
4
5
6
Mode Indicator Lights
Fan speed indicator lights
Power
indicator light
7
TEMP. ADJUST
TIMER ON
TIMER OFF
MODE
FAN SPEED
ION
POWER
COOL
DRY
FAN
MED
HI
LO
F
C
8
HEAT
Operating MODES
1. Press “Mode” button until the “COOL” indicator light
comes on.
2. Press “Temp. Adjust” buttons to select desired
room temperature from 62
˚
F to 88
˚
F (17
˚
C to 30
˚
C).
3. Press “Fan Speed” button to choose fan speed.
NOTE: Some models limit fan speed to LOW when
room temperature is 98
˚F (37˚C) or higher. The system
will not resume a previous fan speed setting until the
room temperature falls below 93˚F (35˚C).
COOL
62
˚
F to 95
˚
F (17
˚
C to 35
˚
C)
For units with PTC only
1. Press “Mode” button until the “HEAT” indicator light
comes on.
2. Press “Temp. Adjust” buttons to select desired
room temperature from 62
˚
F to 88
˚
F (17
˚
C to 30
˚
C).
3. Press “Fan Speed” button to choose fan speed.
Do not connect intake and exhaust ports to window.
For some models fan speed is limited to LOW in
HEAT mode.
Press “Mode” button until the “DRY” (dehumidifying)
indicator light comes on.
• Under this mode, you cannot select a fan speed
or adjust the temperature. The fan motor operates
at LOW speed only.
• Keep windows and doors closed for the best
dehumidifying performance.
• Do not connect intake and exhaust ports to window.
CAUTION: During COOL or DRY modes, if unit power
is interrupted (unplugged, power failure, etc.) and then
immediately restored, a compressor protection circuit
is activated. The compressor cannot operate for
about 3 minutes until the circuit self-deactivates.
DRY
54
˚
F to 95
˚
F (13
˚
C to 35
˚
C)
HEAT
41
˚
F to 88
˚
F (5
˚
C to 30
˚
C)
1. Press “Mode” button until the “FAN” indicator light
comes on.
2. Press “Fan Speed” button to choose fan speed.
The temperature cannot be adjusted.
Do not connect intake and exhaust ports to window.
FAN
All temperatures
When the unit is set to “AUTO” operation, all functions
are transferred to the remote control. All “Mode” and
“Fan Speed” indicator lights will be dark in AUTO mode.
See Remote Control Instruction Guide for control of
unit functions.
AUTO
FOR REMOTE CONTROL
NOTE: Time settings will display for only 5 seconds, so you should continue pressing the buttons until
desired time is reached.