background image

bm

Problem

Possible Causes

Solution

Poor Cooling 
Performance

Temperature setting may 
be higher than ambient 
room temperature

Lower the temperature setting

The heat exchanger on the 
indoor or outdoor unit is 
dirty

Clean the affected heat exchanger

The air filter is dirty

Remove the filter and clean it 
according to instructions

The air inlet or outlet of 
either unit is blocked

Turn the unit off, remove the 
obstruction and turn it back on

Doors and windows are 
open

Make sure that all doors and 
windows are closed while 
operating the unit

Excessive heat is generated 
by sunlight

Close windows and curtains 
during periods of high heat or 
bright sunshine

Too many sources of heat 
in the room (people, 
computers, electronics, 
etc.)

Reduce amount of heat sources

Low refrigerant due to leak 
or long-term use

Check for leaks, re-seal if 
necessary and top off refrigerant

SILENCE function is 
activated (optional function)

SILENCE function can lower 
product performance by reducing 
operating frequency. Turn off 
SILENCE function.

Problem

Possible Causes

Solution

The unit is not 

working

Power failure

Wait for the power to be 

restored

The power is turned off

Turn on the power

The fuse is burned out

Replace the fuse

Remote control batteries are 

dead

Replace batteries

The Unit’s 3-minute protection 

has been activated

Wait three minutes after 

restarting the unit

Timer is activated

Turn timer off

The unit

starts and
stops
frequently

There’s too much or too little 

refrigerant in the system

Check for leaks and 

recharge the system with 

refrigerant.

Incompressible gas or 

moisture has entered the 

system.

Evacuate and recharge the 

system with refrigerant

The voltage is too high or 

too low

Install a manostat to 

regulate the voltage

Poor heating 

performance

The outdoor temperature is 

exetremtly low

Use auxiliary heating 

device

Cold air is entering through 

doors and windows

Make sure that all doors 

and windows are closed 

during use

Low refrigerant due to leak or 

long-term use

Check for leaks, re-seal 

if necessary and top off 

refrigerant

Indicator lamps 

continue flashing

The unit may stop operation or continue to run safely. If 

the indicator lamps continue to flash or error codes appear, 

wait for about 10 minutes. The problem may resolve itself. 
If not, disconnect the power, then connect it again. Turn 

the unit on.
If the problem persists, disconnect the power and contact
Ideal-Air

TM

 technical support.

Error code appears in 

the window display 

of indoor unit:

• 

E0, E1, E2…

• 

P1, P2, P3…

• 

F1, F2, F3…

When troubles occur, please check the following points before contacting a repair company.

NOTE:

If your problem persists after performing the checks and diagnostics above, 

turn off your unit immediately and contact Ideal-Air

TM

 technical support.

Содержание 700021

Страница 1: ...TIONER USER MANUAL This manual only describes the installation of the indoor unit When installing the outdoor unit refer to the installation manual of outdoor unit 700807 700808 PRO DUAL MINI SPLIT I N D O O R W A L L M O U N T ...

Страница 2: ...rsonal property and also poses a personal safety hazard on your purchase of Ideal Air s Pro Mini Split indoor wall mount unit We re proud to offer this product and believe it s the very best in its class 2 SAFETY PRECAUTIONS 3 UNIT SPECIFICATIONS AND FEATURES 4 MANUAL OPERATION 7 CARE AND MAINTENANCE 7 TROUBLESHOOTING 9 DISPOSAL GUIDELINES 13 GLOSSARY OF TERMS 14 CONTENTS ...

Страница 3: ... Call your dealer for instructions to avoid electric shock fire or injury DO NOT insert fingers rods or other objects into the air inlet or outlet This may cause injury since the fan may be rotating at high speeds DO NOT use flammable sprays such as hair spray lacquer or paint near the unit This may cause fire or combustion DO NOT operate the air conditioner in places near or around combustible ga...

Страница 4: ...ded use DO NOT climb onto or place objects on top of the outdoor unit DO NOT allow the air conditioner to operate for long periods of time with doors or windows open CAUTION UNIT SPECIFICATIONS AND FEATURES UNIT PARTS For 3 seconds when TIMER ON is set FRESH SWING TURBO or SILENCE features are turned on For 3 seconds when TIMER OFF is set FRESH SWING TURBO or SILENCE features are turned off When d...

Страница 5: ...perature 18 43 C 64 109 F 7 24 C 19 75 F 11 43 C 52 109 F 7 43 C 19 109 F For models with low temp cooling systems 18 43 C 64 109 F 18 54 C 64 129 F For special tropical models 18 54 C 64 129 F For special tropical models COOL mode HEAT mode DRY mode TO FURTHER OPTIMIZE THE PERFORMANCE OF YOUR UNIT DO THE FOLLOWING Keep doors and windows closed DO NOT block air inlets or outlets Regularly inspect ...

Страница 6: ... hour and will increase an additional 1 C 2 F after another hour When in HEAT mode the unit will decrease the temperature by 1 C 2 F after 1 hour and will decrease an additional 1 C 2 F after another hour It will hold the new temperature for 5 hours then the unit will turn off automatically Range Caution do not keep louver at too vertical of an angle for long periods of time This can cuase water c...

Страница 7: ...ed Press the MANUAL CONTROL button again to activate FORCED COOLING mode Press the MANUAL CONTROL button a third time to turn the unit off Close the front panel The manual button is intended for testing purposes and emergency operation only Please DO NOT use this function unless the remote is lost and it is absolutely necessary To restore regular operation use the remote control to activate the un...

Страница 8: ...its previous display To reset the reminder press the LED button on your remote control 4 times or press the MANUAL CONTROL button 3 times If you don t reset the reminder the CL indicator will flash again when you restart the unit AIR FILTER REPLACEMENT REMINDER After 2 880 hours of use the display window on the indoor unit will flash nF This is a reminder to replace your filter After 15 seconds th...

Страница 9: ...eached at which point the unit turns off the compressor The unit will continue operating when the temperature fluctuates again The indoor unit emits white mist In humid regions a large temperature difference between the room s air and the conditioned air can cause white mist Both the indoor and outdoor units emit white mist When the unit restarts in HEAT mode after defrosting white mist may be emi...

Страница 10: ...ed description of the unit malfunction as well as your model number The indoor unit makes noises A squeaking sound may occur after running the unit in HEAT mode due to expansion and contraction of the unit s plastic parts Both the indoor unit and outdoor unit make noises Low hissing sound during operation This is normal and is caused by refrigerant gas flowing through both indoor and outdoor units...

Страница 11: ...people computers electronics etc Reduce amount of heat sources Low refrigerant due to leak or long term use Check for leaks re seal if necessary and top off refrigerant SILENCE function is activated optional function SILENCE function can lower product performance by reducing operating frequency Turn off SILENCE function Problem Possible Causes Solution The unit is not working Power failure Wait fo...

Страница 12: ...mer off The unit starts and stops frequently There s too much or too little refrigerant in the system Check for leaks and recharge the system with refrigerant Incompressible gas or moisture has entered the system Evacuate and recharge the system with refrigerant The voltage is too high or too low Install a manostat to regulate the voltage Poor heating performance The outdoor temperature is exetrem...

Страница 13: ... or unsorted municipal waste When disposing of this appliance you have the following options Dispose of the appliance at designated municipal electronic waste collection facility SPECIAL NOTICE Disposing of this appliance in the forest or other natural surroundings endangers your health and is bad for the environment Hazardous substances may leak into the ground water and enter the food chain DISP...

Страница 14: ... greater the number rating the more efficient the heating A 10 HSPF for example is a very good rating Humidifier Humidifiers use water to put humidity in the growing space Many plants we grow indoors are accustomed to growing outdoors in tropical areas where humidity is high Also certain parts of the country are drier than others so you will need to add humidity Line Set Insulated copper tubing us...

Страница 15: ..._____________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ __________________________________________...

Страница 16: ... answers to most common questions and a complete technical support library please visit www ideal air com All design and specifications herein are subject to change without notice for product improvement Contact Ideal AirTM for details updates and other information DO NOT return this product to the store where you purchased it ...

Отзывы: