background image

 

 

 

     

   

2.1 Control Panel 

 

Function key

 

1. 

ON/OFF

- Turns the machine on and off. 

2. 

SET

- Press the SET button to set the desired humidity level, 

the range is from 30% to 95%. 

3. 

UP

  DOWN

- Each time you press the “UP” button, the 

humidity will be raised by 1% and by pressing the “DOWN” button, 

the humidity will be lowered by 1%. When the humidity has been 

set, it will flash five times. 

4. When the unit is dehumidifying, the LED display will read in blue 

(running). 

5. When the humidity set point is met, the unit will shut down and 

the LED display will be orange. The unit will automatically start as 

needed to maintain the set humidity level. 

Chapter 2 Control Panel 

Содержание 180 PINT

Страница 1: ...For your safety please remember all of the items as follows Chapter 1 Precautions Do not use with burnt or damaged cord Do not damage the power cord Must be placed on a flat level surface Do not place the dehumidifier in front of an open window that might allow rain to enter No chemical or corrosive object on dehumidifier Do not place the dehumidifier near heat source Do not spill liquid on the de...

Страница 2: ...te etc If service is needed it should be performed by a qualified service technician Always plug into a grounded outlet Keep children away from the dehumidifier 1 2 Proper Care and Daily Maintenance Clean surface with a soft cloth do not use solvents gasoline or a strong detergent Hand wipe only Do not immerse in water If water enters the dehumidifier unplug the unit and contact a qualified servic...

Страница 3: ...will be raised by 1 and by pressing the DOWN button the humidity will be lowered by 1 When the humidity has been set it will flash five times 4 When the unit is dehumidifying the LED display will read in blue running 5 When the humidity set point is met the unit will shut down and the LED display will be orange The unit will automatically start as needed to maintain the set humidity level Chapter ...

Страница 4: ...ier below 59 F frost will form on the evaporator coil The unit will automatically go into defrost mode and melt the frost LED display 1 LED shows the present humidity level 2 E6 Code temperature sensor fault 3 E5 Code Humidity sensor fault Unit Diagram ...

Страница 5: ... 1 Normal Maintenance Clean the unit with soft cloth no liquids or harsh detergent is allowed 2 Maintenance of the Filter The filter should be cleaned every month put it in clean water and then dry it More often if needed 3 Storage Store in a dry and cool place Chapter 3 Water Drainage and Maintenance ...

Страница 6: ...he intake duct or discharge duct obstructed Remove the obstruction from the discharge duct or intake duct No air is discharged Is the air filter clogged Clean the air filter as instructed under Cleaning the dehumidifier Is the unit tilted or unsteady Move the unit to a stable sturdy location Operation is noisy Is the air filter clogged Clean the air filter as instructed under Cleaning the dehumidi...