background image

User Manual

- 4 -

Warranty

Declaration of Conformity

All 

IDEA

 products are guaranteed against any manufacturing defect for a period of 2 years from date of purchase.

The guarantee excludes damage from incorrect use of the product. Any guarantee repair, replacement and servicing must be exclu-

sively done by the factory or any of authorized service centers.
Do not open or intend to repair the product; otherwise servicing and replacement will not be applicable for guarantee repair. Return 

the damaged unit, at shipper’s risk and freight prepaid, with a copy of the purchase invoice in order to claim guarantee service or 

replacement to the nearest service center or, when required by the manufacturer, to 

IDEA

 headquarters at:

I MAS D Electroacústica SL

Pol. A Trabe 28-20, 15350 Cedeira (A Coruña) Galicia - Spain

AllDSP GmbH & Co. KG, Spengler Str. 6, 59067 Hamm, Germany
Declares that the product 

IDEA

 

TEO

d9 conforms to the following Specifications:

•  Safety: IEC 60065 -01+Amd 1
•  EMC : EN 55022:2006
•  EN 55103 -1, -2 2008
•  EN 55024:1998
•  FCC Part 15 

SUPPLEMENTARY INFORMATION

The product herewith complies with the requirements of the:

•  Low Voltage Directive 2006/95/EC
•  EMC Directive 2004/108/EC
•  RoHS Directive 2002/95/EC
•  WEEE Directive 2002/96/EC

With regard to Directive 2005/32/EC and EC Regulation 1275/2008 of 17 December 2008, this product is designed, produced, and 

classified as Professional Audio Equipment and thus is exempt from this Directive.

A molded mains plug that has been cut off from the cord is unsafe. Discard the mains plug at a suitable disposal facility. NEVER 

UNDER ANY CIRCUMSTANCES SHOULD YOU INSERT A DAMAGED OR CUT MAINS PLUG INTO A 13 AMP POWER SOCKET. Do not 

use the mains plug without the fuse cover in place. Replacement fuse covers can be obtained from your local retailer. Replacement 

fuses are 13 amps and MUST be ASTA approved to BS1362. If you want to dispose this product, do not mix it with general house-

hold waste. There is a separate collection system for used electronic products in accordance with legislation that requires proper 

treatment, recovery and recycling. Private household in the 25 member states of the EU, in Switzerland and Norway may return their 

used electronic products free of charge to designated collection facilities or to a retailer (if you purchase a similar new one). For 

Countries not mentioned above, please contact your local authorities for a correct method of disposal. By doing so you will ensure 

that your disposed product undergoes the necessary treatment, recovery and recycling and thus prevent potential negative effects 

on the environment and human health.

ELECTROMAGNETIC COMPATIBILITY

This device complies with part 15 of the FCC Rules and the Product Specifications noted on the Declaration of Conformity. Opera

-

tion is subject to the following two conditions: - this device may not cause harmful interference, and - this device must accept any 

interference received, including interference that may cause undesired operation. Operation of this processor within significant 

electromagnetic fields should be avoided. - Use only shielded interconnecting cables.

Содержание TEOd9

Страница 1: ...TEOd9 4 in 8 out Professional Loudspeaker Management System User Manual ...

Страница 2: ...er Interface Monitoring and permanent logging of key parameters such as temperature signal level and gain reduction 384 600 or 1200 FIR taps per output Dante AES67 AES EBU and AVB MILAN est Q1 2021 Multiple display and GPI GPO support Full customization options 8 DC inputs for potentiometers 8 current measurement AC inputs 8 temperature sensor inputs 100Mbit LAN with loop through Direct Drive capa...

Страница 3: ...gain DSP only 0 003 Frequency Response DSP only 10 40k Hz 0 5 dB DSP 64 bit multimode ALLDSP AM685 Number of processors 4 Sample rate 96 kHz FIR 8x600 taps Presets 250 Delay 2000 in 50 out ms PEQ each input and output 10 bands Crossover each input and output LPF and HPF 48 dB Oct Compressors each input and output 3 bands Limiter switchable true RMS Zero Attack each in and out 1 bands Power Supply ...

Страница 4: ...that has been cut off from the cord is unsafe Discard the mains plug at a suitable disposal facility NEVER UNDER ANY CIRCUMSTANCES SHOULD YOU INSERT A DAMAGED OR CUT MAINS PLUG INTO A 13 AMP POWER SOCKET Do not use the mains plug without the fuse cover in place Replacement fuse covers can be obtained from your local retailer Replacement fuses are 13 amps and MUST be ASTA approved to BS1362 If you ...

Страница 5: ...cularly at plugs convenience receptacles and the point where they exit from the apparatus Refer all servicing to qualified service personnel Servicing is required when the device has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into it the device has been exposed to rain or moisture does not operate normally or has been dropped...

Страница 6: ...MAINS SOCKET OUTLET WITH A PROTECTIVE EARTHING CONNECTION The cores in the mains lead are colored in accordance with the following code GREEN and YELLOW Earth BLUE Neutral BROWN Live As colors of the cores in the mains lead of this appliance may not correspond with the colored markings identifying the terminals in your plug proceed as follows The core which is colored green and yellow must be conn...

Страница 7: ...ese meters refer to the absolute input level multiplied by the input gain The Limit LED lights when any gain reduction is taking place in that channel The CLIP LED lights when the input level reaches 22dBu 1 1 3 FUNCTION BUTTONS The function buttons allow direct access to all editing and navigating functions See section three for a detailed description on the functions of each of these buttons 1 1...

Страница 8: ...s 23dBu max electronically balanced 1 2 4 ETHERNET CONNECTOR The RJ 45 connector is used to connect your product to a network It can then be configured and controlled in real time with the PC and MAC configuration program With this program you can also update your DSP to the latest firmware Please check our website regularly for updates 1 2 5 AES EBU INPUT The digital input of the TEOd9 offers an ...

Страница 9: ...o the Software Manual available on our website for details on the control software 2 1 2 1 STANDARD DHCP NETWORK For the easiest connection use a standard Ethernet Router plug in the unit and your computer and the connection should be made automatically Standard routers have a DHCP server built in and enabled A DHCP server assigns a network address to your computer and to the TEOd9 allowing them t...

Страница 10: ...orrectly setup you will not be using your system to its fullest potential and could result in damage to your speakers To ensure an optimal gain structure Play a signal at the nominal level from your mixing desk and set the input gain of your processor to 0 Set the crossovers that you want to use while keeping the output gains also at 0 With DISCONNECTED loudspeakers turn up the volume of the power...

Страница 11: ...dit Make the first settings with the output turned low or muted To toggle through the different menus press the Item Up or Item Down buttons 3 2 1 GAIN Adjust the gain by dialing the rotary encoder The gain is adjusted in steps of 0 25dB Smaller steps 0 01dB can be set via the PC or MAC IDEA DSPControl software 3 2 2 INPUT SELECTION Select the source Analog or AES EBU by rotating the encoder 3 2 3...

Страница 12: ... by dialing the rotary encoder Press the rotary encoder to select the parameters The available parameters are Frequency 20Hz to 20kHz Gain 12dB to 12dB Q 0 2 to 25 Enabled On or Off Type Bell High Shelf Low Shelf Notch All Pass Band Pass High Pass Low Pass For the Shelving filters the Q value sets the steepness of the filter in dB Oct 3 2 7 COMPRESSOR The compressor is a true RMS compressor Turn t...

Страница 13: ...the Low Pass Filter frequency by turning the rotary encoder You can switch the low pass filter off by turning the rotary encoder up clockwise until the frequency passes 20kHz Press the rotary encoder to change the filter type Select the type by turning the rotary encoder You can choose from Butterworth 6dB Bessel 6dB Butterworth 12dB Bessel 12dB Linkwitz Riley12dB Butterworth 18dB Bessel 18dB Butt...

Страница 14: ...ness of the filter in dB Oct 3 3 7 COMPRESSOR The compressor is a true RMS compressor Turn the rotary encoder to set the threshold Press the rotary encoder to select the parameters The available parameters are Threshold Attack Hold Release Ratio and Makeup Gain 3 3 8 LIMITER The limiter is a zero attack peak limiter Only the threshold and release can be set Press the rotary encoder to select the p...

Страница 15: ...e selected location The presets contain all filter dynamics gain settings etc Presets do NOT contain the name of the unit network configuration automatic standby delay user access rights and passwords 3 4 3 ACCESS LEVEL The TEOd9 has the option of locking away the front panel controls to avoid tampering of settings by unauthorized persons To lock the unit select Locked by turning the rotary encode...

Страница 16: ...A SL Pol A Trabe 19 20 15350 Cedeira A Coruña España Spain Tel 34 881 545 135 www ideaproaudio com info ideaproaudio com Specifications and product appearance may be subject to change without notice UM_TEOd9_EN_v1 0 06 2022 ...

Отзывы: