![ICU 4457.230V.50HZ.16A.1FNPE.2X16A.DRUAST Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/icu/4457-230v-50hz-16a-1fnpe-2x16a-druast/4457-230v-50hz-16a-1fnpe-2x16a-druast_manual_615304008.webp)
8
Commissioning
1. Connect the power to the power supply cable. The EVe will show
different LED indicators. Ultimately, the LED will switch off and the
charging point will be ready for use.
2. Take the following steps in case of an error message:
a. Check the earthing connection.
b. Check whether the phase and neutral have been connected
correctly.
c.
Switch off the power from the charging point for at least 1
minute.
d. Again switch on the power.
Product specifications
1-phase model
3-phase model
Housing
SMC (fibreglass strengthened plastic)
Dimensions
H 590 x W 338 x D 230 mm
Weight
approximately 15 kg
approximately 25kg
Protection value
IP54
Charging mode
Mode 3
Socket
Type 2
Ambient temperature
-30°C to +40°C
Max. air humidity
95%
Standby consumption
approx. 20 W
Standard
IEC 61851-1 (2010) and
IEC 61851-22 (2001)
CE Directives
Low voltage directive 2006/95/EC and
EMC directive 2004/108EC
RFID*
Meets ISO15693 and ISO14443
Local Area Network*
At least CAT5 Ethernet (TCP/IP)
GPRS
900/1800 Mhz
* Specific models