ICT TS-0698 Скачать руководство пользователя страница 10

10

5.2 Controlling the different address cameras

Changing the phisical address of the cameras and controlling the rotation from the PC

software to realize mutiple cameras on-line using.

5.3 System on-line testing

Connecting two conference controllers, 9 units of TS series delegates, 9 units of TH series

delegates and the PC, then turn on the PC software. Setting the ID number on the

delegates and the pre-setting of each delegate. Then begin the microphone testing.

Checking if the camera rotation is correct or not when turning on several delegates or

turning off several delegates. There are several standards to judge if the rotation is correct

or not.

1) TS series and TH series conference systems should be tested interdependent, which

could not be tested as the same system.

2) For example, when turning on the 1

st

, 2

nd

, 3

rd

, 4

th

, 5

th

delegate continuously, the camera

will point to the 5

th

delegate. When the 5

th

delegate is turned off, the camera will point to

the 4

th

delegate; Switching off the delegates in turns, the camera will point to the

panoramic position. (The panoramic position should be setted by the PC software;

adjusting the camera position and then click it)

3) For example, when turning on the 1

st

, 2

nd

, 3

rd

, 4

th

, 5

th

delegate continuously, the camera

will point to the 5

th

delegate. Then switching off the 2

nd

, 3

rd

, 4

th

delegates, the camera

position will not be changed. Then turn off the 5

th

delegate, at this time the camera will turn

to the 1

st

delegate.

4) For example, when turning on the 1

st

, 2

nd

, 3

rd

, 4

th

, 5

th

delegate continuously, the camera

will point to the 5

th

delegate. Then press the priority key of the 6

th

delegate, all the

delegates will turn off the mic and the camera will turn to the 6

th

delegate. Both TS and TH

delegates are in the same testing.

Содержание TS-0698

Страница 1: ...Intelligent digital conference system User Manual TS 0698 Please Read This Manual Before Operation...

Страница 2: ...rameters change later another supply mentary instruction will be added the details can be inquired to the manufacturers This manual is a product manufacturer Copyright unauthorized and any entity or i...

Страница 3: ...is risk of shock 3 Do not put the unit in extremely cold or hot place 4 The unit will be heating when working Please keep environment ventilation to avoid overheating 1 Please power off the unit in w...

Страница 4: ...long distance telephone meeting voting and camera tracking system In order with the concept of the all along proposed overall system integration solution tight compatibility between the two different...

Страница 5: ...d rate are supported 5 RS232 and RS485 communication modes are supported 6 Image freezing function can be custom made according to customer s need Introduction of the principle of camera shooting and...

Страница 6: ...source output 2 way to OUT Should after electricity access video signal the output is the default of the thrust line of the video signal source all the way 7 HDMI OUT Output HDMI high definition video...

Страница 7: ...ave the save function when the power cutout 2 Obtaining the dates of DIP switch The factory default setting is at OFF position 1 Dialing the DIP switch on the rear of the unit after re power on only e...

Страница 8: ...era at 2400 Dial the 4th bit to select the baud rate of the camera at 4800 Dial both the 3rd and 4th bits to select the baud rate at 19200 Neither the 3rd nor the 4th bit is dialed which means to sele...

Страница 9: ...ate and then click SAVE to finish the setting progress Settiing all the pre setting positions of the delegates in sequence to make sure the camera poins automatically when any delegate turns on 2 Afte...

Страница 10: ...For example when turning on the 1st 2nd 3rd 4th 5th delegate continuously the camera will point to the 5th delegate When the 5th delegate is turned off the camera will point to the 4th delegate Switch...

Страница 11: ...table of TS 0698 means the testing function is valid means the testing fuction is invalid TS series tracking TS series tracking control Serial port control Channel switching VISCA protocol SAMSUNG pro...

Отзывы: