Humidity
0%-93% non-condensing, indoor use only (relative humidity)
Mean Time Between Failures
(MTBF)
622,997 hours (calculated using RFD 2000 (UTE C 80-810) Standard)
*
The total combined current refers to the current that will be drawn from the external power supply to supply the
expander
and
any devices connected to its outputs. The auxiliary outputs are directly connected via thermal
resettable fuses to the N+ N- input terminals, and the maximum current is governed by the trip level of these fuses.
** Each reader port supports either Wiegand or RS-485 reader operation, but
not both at the same time
. If
combining reader technologies, they must be connected on separate ports.
The ICT implementation of OSDP conforms to a subset of the OSDP functionality. For specifications and reader
configuration, refer to
Application Note 254: Configuring OSDP Readers
, available from the ICT website.
It is important that the unit is installed in a dry cool location that is not affected by humidity. Do not locate the unit
in air conditioning or a boiler room that can exceed the temperature or humidity specifications.
Integrated Control Technology continually strives to increase the performance of its products. As a result these
specifications may change without notice. We recommend consulting our website (www.ict.co) for the latest
documentation and product information.
PRT-RDM2-DIN-485 | Protege DIN Rail 2 Door Reader Expander | Installation Manual
29