Technical Specifications
The following specifications are important and vital to the correct operation of this product. Failure to adhere to
the specifications will result in any warranty or guarantee that was provided becoming null and void.
Ordering Information
PRT-PSU-DIN-4A
Protege DIN Rail 4A Intelligent Power Supply
Power Supply
Mains Input Voltage
120VAC (90-264VAC, 47-63Hz)
Mains Input Operating
Current
120VAC 1500mA (Full Load)
DC Output (Combined)
12.64VDC 4.0A Max (V1 Out + V2 Out Total)
DC Output (Single)
12.2VDC 3A Max
Battery Charging
500mA (Typical)
*Additional to the 4A Combined DC Output
Battery Low
11.75VDC
Battery Restore
12.5VDC
Communication
RS-485
Isolated Module Network
Outputs
Outputs
2 Solid-State Relay Outputs, 50mA 12V Max each
Inputs
Tamper
Dedicated Hardware Tamper Input
Trouble Inputs
8 (internal)
Dimensions
Dimensions (L x W x H)
156.8 x 90 x 60mm (6.17 x 3.54 x 2.36")
Weight
434g (15.33oz)
Operating Conditions
Operating Temperature
UL/ULC 0° to 49°C (32° to 120°F) : EU EN -10° to 55°C (14° to 131°F)
Storage Temperature
-10˚ to 85˚C (14˚ to 185˚F)
Humidity
0%-93% non-condensing, indoor use only (relative humidity)
Mean Time Between Failures
(MTBF)
242,266 hours (calculated using RFD 2000 (UTE C 80-810) Standard)
It is important that the unit is installed in a dry cool location that is not affected by humidity. Do not locate the
unit in air conditioning or a boiler room that can exceed the temperature or humidity specifications.
Integrated Control Technology continually strives to increase the performance of its products. As a result these
specifications may change without notice. We recommend consulting our website (www.ict.co) for the latest
documentation and product information.
PRT-PSU-DIN-4A | Protege DIN Rail 4A Intelligent Power Supply | Installation Manual