Содержание PRT-MNR2-DIN

Страница 1: ...PRT MNR2 DIN Protege Module Network Repeater Installation Manual ...

Страница 2: ... or mechanical for any purpose without the express written permission of Integrated Control Technology Limited Designed and manufactured by Integrated Control Technology Limited Protege and the Protege Logo are registered trademarks of Integrated Control Technology Limited All other brand or product names are trademarks or registered trademarks of their respective holders Copyright Integrated Cont...

Страница 3: ...etwork Expansion 15 Network Repeater Configuration 17 Logging in for the First Time 17 Configuration 17 Device Information 19 User Management 19 LED Indicators 20 Power Indicator 20 Status Indicator 20 Fault Indicator 20 Ethernet Indicator 20 COM Indicators 21 Mechanical Diagram 22 Mechanical Layout 23 Technical Specifications 24 New Zealand and Australia 25 European Standards 26 FCC Compliance St...

Страница 4: ...PRT MNR2 DIN Protege Module Network Repeater Installation Manual 4 ...

Страница 5: ... building automation The network repeater is added to the system via RS 485 or ethernet and provides optical isolation between up to three branches of the module network easing power requirements The current features of the network repeater include 3 isolated RS 485 connections 10 100 ethernet RS 485 or ethernet network expansion Secure encrypted RS 485 module communications PRT MNR2 DIN Protege M...

Страница 6: ...equipment is to be installed in accordance with The product installation instructions AS NZS 2201 1 Intruder Alarm Systems The Local Authority Having Jurisdiction AHJ PRT MNR2 DIN Protege Module Network Repeater Installation Manual 6 ...

Страница 7: ...e copper wire or wires of the appropriate gauge Earth Ground Connection The DIN rail enclosure and the DIN rail modules must be grounded to a suitable single point earth ground connection in the installation A minimum 14AWG solid copper wire or thicker in accordance with local authorities shall be used from the Protege system s earth connection points The DIN rail enclosure includes an earth groun...

Страница 8: ...round Link Connection DIN Rail Enclosure DIN Rail Enclosure DIN Rail Enclosure Module Network RS 485 N N NA and NB DIN Rail Ground Connections multiple cabinets in different rooms sectors or buildings Note that the DIN rail enclosure earth terminal is connected to the power supply V terminal There must be only one single earth grounding point per system PRT MNR2 DIN Protege Module Network Repeater...

Страница 9: ... is installed in an electrical room communication equipment room secure cabinet or in an accessible area of the ceiling 1 Position the DIN rail module with the labeling in the correct orientation 2 Hook the mounting tabs opposite the tab clip under the edge of the DIN rail 3 Push the DIN rail module against the mount until the tab clips over the rail Removal A Protege DIN rail module can be remove...

Страница 10: ...COM1 module network spur as well as long as the maximum load of the power supply is not exceeded B B L N NA N N NB Module Network Expander Power Supply Gel Cell Backup Battery V1 V V1 V1 V1 V1 V1 V V V V V Ethernet Network Connection Mains Input N N NA NB To other Modules on Network If the network repeater is inserted into an existing section of the module network the auxiliary outputs of a contro...

Страница 11: ...te module network spurs when the network repeater is connected via ethernet In this scenario COM1 is only used for supplying power to the network repeater The COM2 and COM3 ports are powered separately and are optically isolated from each other An independent battery backed power supply unit is required for each spur B B L N NA N N NB Power Supply V1 V V1 V1 V1 V1 V1 V V V V V To other Modules on ...

Страница 12: ... input from the Controller or previous module It is important that the N network communications power be 12VDC supplied from an independent battery backed power supply unit capable of supplying the required voltage to all devices on the RS 485 network Always connect the NA and NB terminals of the network repeater to the NA and NB terminals of the communication network The N and N must go to a 12V ...

Страница 13: ...d of Line EOL Resistors The 330 ohm EOL End of Line resistor provided in the accessory bag must be inserted between the NA and NB terminals of the first and last modules on the RS 485 network These are the modules physically located at the ends of the RS 485 network cabling 330R 330R First Module on RS 485 Network Last Module on RS 485 Network To Next Module From Previous Module NA N N NB NA N N N...

Страница 14: ...sing a standard segment 100m in length and should be connected to a suitable ethernet hub or switch Installing the module on an active network requires knowledge of the configuration and structure for the network Always consult the network or system administrator and ask them to provide you with a fixed IP address that can be assigned to the module Ethernet 10 100 Switch Hub Connection Temporary d...

Страница 15: ...long distance runs Extending the LAN using ethernet to remove the need to run expensive cabling over long networks Creating isolated RS 485 networks for keypads or devices located outside or in publicly accessible areas Situations where there are physical locations where wiring is difficult Extending the RS 485 module network While the maximum length of the RS 485 module network is 900m 3000ft the...

Страница 16: ...o strengthen communications or resolve network issues Network Expansion using RS 485 Expander Network Expander Expander Controller Expander Keypad Expander Keypad Main RS 485 Network Isolated RS 485 Networks PRT MNR2 DIN Protege Module Network Repeater Installation Manual 16 ...

Страница 17: ...RNET N N NA NB 12VDC IN OUT RS 485 NETWORK When attempting to view the web interface from a network that uses a proxy server ensure the browser connection options are configured to recognize local addresses Logging in for the First Time 1 Open a web browser and enter the default IP address of 192 168 1 3 2 Enter the default operator login of admin with the password admin For security reasons this ...

Страница 18: ...ific port Repeater Config The module needs to know which controller it should communicate with and the mode to be used Repeater Mode Defines the method that the module uses to communicate with the controller By default this is set to RS 485 RS 485 mode When in RS 485 mode all module network packets received on COM2 and COM3 are forwarded to COM1 All packets received on COM1 are forwarded to COM2 a...

Страница 19: ...ode then transferring a firmware file to the device by TFTP User Management The module comes with two default users Username Password admin admin user user When logged in as admin the operator can access all pages and change any parameter In comparison the user account permits access to the main home and device information pages To edit a user click on the appropriate checkbox then click Edit This...

Страница 20: ... applied Status Indicator The status indicator displays the status of the module State Description Continuous slow flash green Module is operating normally Constantly on green Module is powering up Fault Indicator The fault indicator is lit any time the module is operating in a non standard mode State Description Continuous slow red flash Module is in boot mode awaiting firmware update Ethernet In...

Страница 21: ...OM indicators shows the status of the three COM ports State Description Constantly on red COM port is not powered Constantly on green COM port is powered PRT MNR2 DIN Protege Module Network Repeater Installation Manual 21 ...

Страница 22: ...installation of the network repeater COM Port Indicators Ethernet Connection RS 485 COM Ports Status Indicators RS 485 COM Port NB NA N N COM3 POWER STATUS FAULT ETHERNET COM2 NB NA N N COM2 COM3 COM1 ETHERNET N N NA NB 12VDC IN OUT RS 485 NETWORK PRT MNR2 DIN Protege Module Network Repeater Installation Manual 22 ...

Страница 23: ... essential details needed to help ensure correct installation and mounting All measurements are shown in millimeters 90 00 78 40 44 68 67 18 4 67 Screw Hole 39 20 39 20 78 40 17 55 35 40 Back Front PRT MNR2 DIN Protege Module Network Repeater Installation Manual 23 ...

Страница 24: ... Dimensions L x W x H 78 x 90 x 60mm 3 07 x 3 54 x 2 36 Net Weight 150g 5 3oz Gross Weight 220g 7 8oz Operating Conditions Operating Temperature 10 to 55 C 14 to 131 F Storage Temperature 10 to 85 C 14 to 185 F Humidity 0 93 non condensing indoor use only relative humidity It is important that the unit is installed in a dry cool location that is not affected by humidity Do not locate the unit in a...

Страница 25: ...ralia General Product Statement The RCM compliance label indicates that the supplier of the device asserts that it complies with all applicable standards PRT MNR2 DIN Protege Module Network Repeater Installation Manual 25 ...

Страница 26: ...e waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance with your national legislation For business users in the European Union If you wish to discard electrical and electronic equipment please contact your dealer or supplier for further information Informatio...

Страница 27: ...powered detector per input Do not mix unpowered detectors and non latching powered detectors on an input To comply with EN 50131 1 the Entry Timer should not be programmed to more than 45 seconds To comply with EN 50131 1 the Bell Cut Off Time should be programmed between 02 and 15 minutes EN 50131 1 requires that detector activation LEDs shall only be enabled during Walk Test This is most conveni...

Страница 28: ...ons This device may not cause harmful interference This device must accept any interference received including interference that may cause undesired operation NOTE THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE SUCH MODIFICATIONS COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT PRT MNR2 DIN Protege Module Netwo...

Страница 29: ...ment ICES 003 This is a Class A digital device that meets all requirements of the Canadian Interference Causing Equipment Regulations CAN ICES 3 A NMB 3 A PRT MNR2 DIN Protege Module Network Repeater Installation Manual 29 ...

Страница 30: ...shall be liable under any circumstances to any party in respect of decisions or actions they may make as a result of using this information In accordance with the ICT policy of enhanced development design and specifications are subject to change without notice For warranty information see our Standard Product Warranty PRT MNR2 DIN Protege Module Network Repeater Installation Manual 30 ...

Страница 31: ...laimer Whilst every effort has been made to ensure accuracy in the representation of this product neither Integrated Control Technology Ltd nor its employees shall be liable under any circumstances to any party in respect of decisions or actions they may make as a result of using this information In accordance with the ICT policy of enhanced development design and specifications are subject to cha...