Device Settings
From the
Device Settings
menu, you can configure the entry station's network settings.
Network Configuration
This tab allows you to edit the IP address and other connection settings of the entry station.
Programming the IP address, subnet mask, and default gateway requires knowledge of the network and subnet
that the system is connected to. You should always consult the network or system administrator before
programming these values.
1.
Navigate to the
Device Settings
menu and select the
General
tab.
2.
If you require the entry station to request its network configuration settings from a local DHCP server, select
the
DHCP client enabled
option. The remaining network settings will then become unavailable.
3.
Enter the
IP Address
of the entry station.
The default is 192.168.1.34
4.
Leave the DNS IP field blank. This is reserved for future use.
5.
Enter the
Network Mask
used by the entry station. The network mask is used in conjunction with the above IP
addresses. A network mask must be configured to allow access to the appropriate node on the subnet. By
default this is set to a value of 255.255.255.0
6.
Enter the
Default Gateway
used by the entry station. Use the gateway to allow access to a router for external
communications beyond the subnet where the entry station is located. By default this is set to a value of
192.168.1.1.
Changes to the default gateway field will require you to power cycle your entry station.
The
Controller
settings below are only required when integrating the entry station with a Protege GX or
Protege WX system. These options do not apply when the entry station is used in standalone mode. Refer to
the relevant integration section for Protege GX (see page 30) or Protege WX (see page 43) for full
programming details.
7.
The
Con IP Address
is the IP address of the controller that the entry station communicates with.
8.
The
Mod TX Port
is the port that the entry station communicates with the controller.
9.
The
Address
is the keypad address assigned to the entry station for door control.
The
Wiegand Output Configuration
settings below are only relevant when using the Wiegand output.
10.
For the
Wiegand Keypad Format
, select which Wiegand format the entry station should use when PIN codes
are entered via phone calls or the onscreen keypad.
11.
For the
Site Code
option, set which site code to use for Wiegand keypad formats that require a fixed site code
(26 Bit, 36 Bit IEI)
The
External Network
setting below is only relevant when using the entry station with the Protege Mobile
App.
12.
The
External JPEG Video Port
is used to configure which external port the Protege Mobile App uses to reach
the entry stations camera feed.
-
If the entry station is directly accessible via the internet, this should be set to 8080.
-
If the entry station has been port forwarded through a NAT, this should be set to the port number where
http://{ENTRIPADDRESS}:8080/video
is internet accessible.
13.
Click
Save
.
14.
If you have changed the
Default Gateway
, power cycle the entry station to implement the new setting.
PRT-ENTR-17 | Protege Vandal Resistant Touchscreen Entry Station | Installation Manual
25