ELECTRIC BICYCLE METER KT

LCD7C Product User Manual

 

 

- 10 - 

 

○ 

Brake status display 

Under normal operation, vehicle brake, brake status indicator display 

(

)

, as 

shown in the figure. 

       

 

 

Battery Capacity Indicator 

The  meter  can  automatically  identify  24V,  36V,  48V  battery  capacities  when  it  is 

supporting  use  with  the  specified  controller.  When  the  battery  capacity  is  over  70%,  the 

four power displays of the meter are lit, when the battery capacities drop, the four power 

displays  are  off  in  order,  when  the  power  capacity  is  less  than  15%,  the  four  power 

displays are totally turned off. 

When  the  controller  is  power  off  due  to  voltage  shortage,  the  power  display  frame 

flashes,  indicating  the  vehicle  has  been  in  voltage  shortage  and  waiting  for  shutdown 

currently. 

  

 

 

 

Voltage shortage flashes   

                                                        Battery capacity indicator 

○ 

Environment Temperature 

After startup, the environment temperature for using meter will be displayed in 

Содержание KT-LCD7C

Страница 1: ...User Manual KT LCD7C eBike Special Meter www emotoer com...

Страница 2: ...6 Normal Operation 7 On Off 7 Display Interface 7 Display of Turned on Throttle 8 PAS Ratio or Throttle Gear Switch 8 Push Function 9 Cruise Function 9 Turn On Off Backlight 10 Battery Capacity Indica...

Страница 3: ...io Gear Initialization Setting 21 C4 Throttle Function Setting 21 C5 Controller Maximum Current Adjustment Setting 23 C6 Backlight Brightness Adjustment Setting 24 C7 Cruise Function Setting 24 C8 Mot...

Страница 4: ...C Parameter Setting 35 Parameter Copy 36 User Setting Note 36 Version Information 36 Preface The illustrated manual will help you understand and be familiar with the meter function guiding you on how...

Страница 5: ...otor This manual covers installation operation parameter setting of the meter and how to use it properly which help you resolve the problems appeared in practical use Outlook and Size Meter Dimension...

Страница 6: ...ovide you with a variety of functions such as vehicle controls and vehicle status digitized displays to meet the trip demands Trip time display with displays of a single trip time TIM and total trip t...

Страница 7: ...form with part design buttons Normal Operation On Off Hold button SW long the meter is powered on and into normal operation and it provides the controller with power supply Under normal operating sta...

Страница 8: ...tartup to enter display 1 Display 1 Display 2 In display 1 press button SW to enter display 2 Display 2 Display 3 In display 2 press button SW to enter display 3 Display 3 In display 3 press button SW...

Страница 9: ...gear PAS changing motor output power Switching range is 0 5 gear this can also be configured according to the customer requirements gear 1 is for the lowest power and gear 5 is for the highest power...

Страница 10: ...le speed is more than 7 km h and the cruise function logo lights Brake or hold any button to revoke cruise function Startup Backlights and Headlights Hold button UP long the meter turns on the backlig...

Страница 11: ...over 70 the four power displays of the meter are lit when the battery capacities drop the four power displays are off in order when the power capacity is less than 15 the four power displays are tota...

Страница 12: ...y 1 hold both the button UP and the button DOWN simultaneously for about 2 seconds the single trip time TM and single trip distance DST flicker then press button shortly SW the record contents of both...

Страница 13: ...erature alarm Under any interface when the motor operating temperature exceeds the warning value the motor operating temperature display flashes to alarm meanwhile the controller will offer the approp...

Страница 14: ...minute and then the meter will automatically return to display 1 and the original set values will be saved After finishing the maximum riding speed setting Press button SW to save the current set valu...

Страница 15: ...d and mileage unit flash Press button UP or button DOWN to make sync selection of three metric imperial units as speed mileage and the environment temperature Setting Interface of Metric Imperial Unit...

Страница 16: ...will automatically return to display 1 and the original set parameters will be saved P Parameter Setting After finishing metric imperial unit settings the speed and mileage units stop flashing Within...

Страница 17: ...the pulse signal system and then P2 parameter setting can be 0 The setting range of P2 should be between 0 6 press button UP or button DOWN for selection Under P2 parameter setting interface if there...

Страница 18: ...button UP or button DOWN for selection P4 Handlebar Startup Setting Enter P4 parameter setting interface P4 parameter column flashes P4 parameter setting interface P4 is handlebar startup setting when...

Страница 19: ...n stops flashing Press button SW again the meter re enter P1 parameter setting interface Or hold button SW for about 2 seconds to exit P parameter setting environment and return to the display 1 Exit...

Страница 20: ...TENG power assist sensors C1 value Start Sensitivity KUNTENG V12 power assist sensors C1 value Start Sensitivity Forward 5 Signal 00 Standard Reverse 6 Signal 05 Standard 01 Lower 06 Lower 02 Lowest 0...

Страница 21: ...dicating a particular motor phase is used C2 setting range is 0 1 press button UP or button DOWN for selection After finishing C2 parameter setting press button SW to save the current set values and e...

Страница 22: ...the current set values and enter C4 parameter setting interface C4 Handlebar Function Setting Enter C4 parameter setting interface C4 parameter column flashes C4 parameter setting interface C4 is han...

Страница 23: ...gear speed accounts for its full speed of the power assist gear flashes press UP button or DOWN button for short to make selection and the default value is 50 The percentage values of other gears div...

Страница 24: ...alue is controller maximum operating current value ie limit current value when setting is 9 maximum current value divided by 1 10 when setting is 8 maximum current value divided by 1 15 and so on Afte...

Страница 25: ...tting interface C7 parameter column flashes C7 parameter setting interface C7 is cruise function setting the setting range is 0 or 1 press button UP or button DOWN for selection C7 parameter definitio...

Страница 26: ...otor operating temperature display requires installing temperature sensor in the motor output temperature detection signal simultaneously After finishing C8 parameter setting press button SW to save t...

Страница 27: ...each setting and enter next setting Password setting range is 000 999 press button UP or button DOWN for selection Please note If you forget your password the parameters can only be copied see parame...

Страница 28: ...10 selects n press button SW to save the current set values and enter C11 parameter setting interface C11 Meter Attribute Selection Setting Enter C11 parameter setting interface C11 parameter column f...

Страница 29: ...ting press button SW to save the current set values and enter C12 parameter setting interface C12 Controller Minimum Voltage Adjustment Setting Enter C12 parameter setting interface C12 parameter colu...

Страница 30: ...is 4 namely controller minimum operating voltage voltage shortage value when setting is 5 the default value plus 0 5V when setting is 4 the default value minus 0 5Vand so on After finishing C12 param...

Страница 31: ...caution for use Be sure to note 1 the higher is the braking intensity level and the braking strength will be greater the greater damage to the motor shaft accordingly 2 If the battery has a BMS functi...

Страница 32: ...meters Setting Enter C15 parameters setting interface C15 flashes C15 is the setting of push assist speed default value is 6 range from 4 6 press UP button or DOWN button to choose C15 parameters C15v...

Страница 33: ...en L1 1 the under voltage value of the automatic under voltage controller is forced to be 20V When L1 2 the under voltage value of the automatic under voltage controller is forced to be 30V When L1 3...

Страница 34: ...of the factory is 1 When L3 0 the controller will activate Non Hall model only when the Hall sensor in the motor fails When L3 1 the controller will choose the proper model to use according to the co...

Страница 35: ...ile the current set parameters would be saved Under each parameter setting interface if there s no button operation on the meter for more than 1 minute and then the meter will automatically return to...

Страница 36: ...or 24V is available VB positive power supply After wiring the meter needs to be copied hold button long till meter is startup Within 5 seconds after startup hold button UP and button DOWN simultaneous...

Страница 37: ...environment if there s no button operation on the data for more than 1 minute the meter will automatically return to display1 and the new set parameters won t be saved The factory parameter set value...

Отзывы: