User Manual
KT-LCD10H e-Bike Special Meter
www.emotoer.com
Страница 1: ...User Manual KT LCD10H e Bike Special Meter www emotoer com...
Страница 2: ...n 5 22 2 handlebar diameters install icon 6 Physical installation icon 6 Function Overview 6 Display Content 7 Button Definition 7 Normal Operation 8 On Off 8 Display Interface 8 Display 1 8 Display 2...
Страница 3: ...Setting 21 P3 Power Assist Control Mode Setting 21 P4 Throttle Startup Setting 22 P5 Power Monitoring Setting 22 Exit P Parameter Setting 23 C Parameter Setting 23 C1 Power assist Sensor and Paramete...
Страница 4: ...roller and parameters of anti charge control Setting 34 C14 Power assist Tuning Parameters Setting 35 C15 Push assist Speed Parameters Setting 36 Exit C Parameter Setting 36 L parameters Setting 37 L1...
Страница 5: ...the project parameters how to achieve the best match of the three as motor controller and meter to improve electronic control performance of the electric motor This manual covers installation operatio...
Страница 6: ...on The meter body and button box are mounted on the handlebars of the electric vehicle adjusting perspective In the case that the vehicle is power off the meter connectors are in plug connection to co...
Страница 7: ...10H meter provide you with a variety of functions such as vehicle controls and vehicle status digitized displays to meet the trip demands Trip time display with displays of a single trip time TM and t...
Страница 8: ...witch 6Km H power assistant push function Cruise function CRUISE Battery capacity indicator Real time battery voltage VOL display Motor power and temperature MOTOR W display Brake display Turn on back...
Страница 9: ...eter is powered on and into normal operation and it provides the controller with power supply Under normal operating status hold button SW long the meter is powered off meanwhile to shutdown the power...
Страница 10: ...apacity Indicator Single Trip Time TM Display Power Assist Ratio Gear ASSIST Real time Trip Speed Km H Single Trip Distance 6Km H Power Assist Function Motor Operation Power Environment Temperature Ba...
Страница 11: ...splay 2 Total Trip Time TTM Total Trip Distance ODO Single Average Speed AVS Motor Operating Temperature In the riding mode after 5 seconds display 2 automatically returns to display 1 In display 1 th...
Страница 12: ...me trip speed Km H as shown in the icon In display 3 press button SW again to enter display 1 In each display interface if you hold button SW long the meter will be powered off together with that of t...
Страница 13: ...ar Gear Switch Under normal operation press button UP or button DOWN to switch the power assist ratio or handlebar gear ASSIST changing motor output power Switching range is 0 5 gear this can also be...
Страница 14: ...see C parameter setting the meter turns on cruise function hold button DOWN long to enter the cruise status when the vehicle speed is more than 7 km h and the cruise function logo CRUISE lights Brake...
Страница 15: ...ies drop the four power displays are off in order when the power capacity is less than 15 the four power displays are totally turned off When the controller is power off due to voltage shortage the po...
Страница 16: ...erating temperature exceeds the warning value temperature display flashes to alarm meanwhile the motor controller will offer the appropriate protection to motor Environment Temperature After startup t...
Страница 17: ...of both will be cleared Single data clearing display Under the status of data flashing if there were no operations on the data within 5 seconds the meter will automatically return to display1 after 5...
Страница 18: ...offer the appropriate protection to motor User Setting Project KT LCD10H meter user setting project General project setting P parameter setting C parameter setting L parameter setting General Project...
Страница 19: ...um riding speed setting enter the wheel diameter setting interface and then the wheel diameter display column flashes Press button UP or button DOWN to choose the corresponding wheel diameter specific...
Страница 20: ...y Metric Imperial Riding speed Km H MPH Total distance Km Mil Environment temperature Temperature Fahrenheit Under the metric imperial units setting interface if there s no button operation on the met...
Страница 21: ...ld button UP and button DOWN simultaneously for about 2 seconds to enter P parameter setting environment P1 Motor Characteristic Parameter Setting P1 is motor characteristic parameter setting P1 motor...
Страница 22: ...button DOWN for selection Under P2 parameter setting interface if there s no button operation on the meter for more than 1 minute and then the meter will automatically return to display 1 and the ori...
Страница 23: ...tting method is the same to that of P2 P4 Handlebar Startup Setting Enter P4 parameter setting interface P4 parameter column flashes P4 parameter setting interface P4 is handlebar startup setting when...
Страница 24: ...save current set the values and then P5 parameter column stops flashing Press button SW again the meter re enter P1 parameter setting interface Or hold button SW for about 2 seconds to exit P paramet...
Страница 25: ...r button DOWN for selection C1 parameter definition table KUNTENG power assist sensors C1 value Start Sensitivity KUNTENG V12 power assist sensors C1 value Start Sensitivity Forward 5 Signal 00 Standa...
Страница 26: ...or phase is an ordinary one When the setting is a certain value indicating a particular motor phase is used C2 setting range is 0 1 press button UP or button DOWN for selection After finishing C2 para...
Страница 27: ...tdown last time After finishing C3 parameter setting press button SW to save the current set values and enter C4 parameter setting interface C4 Handlebar Function Setting Enter C4 parameter setting in...
Страница 28: ...20 When C4 4 is confirmed the percentage value of the first gear speed accounts for its full speed of the power assist gear flashes press UP button or DOWN button for short to make selection and the...
Страница 29: ...setting is 10 maximum current value is controller maximum operating current value ie limit current value when setting is 9 maximum current value divided by 1 10 when setting is 8 maximum current valu...
Страница 30: ...C7 parameter setting interface C7 parameter column flashes C7 parameter setting interface C7 is cruise function setting the setting range is 0 or 1 press button UP or button DOWN for selection C7 par...
Страница 31: ...otor operating temperature display requires installing temperature sensor in the motor output temperature detection signal simultaneously After finishing C8 parameter setting press button SW to save t...
Страница 32: ...each setting and enter next setting Password setting range is 000 999 press button UP or button DOWN for selection Please note If you forget your password the parameters can only be copied see parame...
Страница 33: ...C10 selects n press button SW to save the current set values and enter C11 parameter setting interface C11 Meter Attribute Selection Setting Enter C11 parameter setting interface C11 parameter column...
Страница 34: ...tting press button SW to save the current set values and enter C12 parameter setting interface C12 Controller Minimum Voltage Adjustment Setting Enter C12 parameter setting interface C12 parameter col...
Страница 35: ...is 4 namely controller minimum operating voltage voltage shortage value when setting is 5 the default value plus 0 5V when setting is 4 the default value minus 0 5Vand so on After finishing C12 param...
Страница 36: ...her is the braking intensity level and the braking strength will be greater the greater damage to the motor shaft accordingly 2 If the battery has a BMS function disable this function After finishing...
Страница 37: ...tting interface C15 flashes C15 is the setting of push assist speed default value is 6 range from 4 6 press UP button or DOWN button to choose C15 parameters C15valte Push assist speed 4 4Km H 5 5Km H...
Страница 38: ...ge value according to the battery voltage When L1 1 the under voltage value of the automatic under voltage controller is forced to be 20V When L1 2 the under voltage value of the automatic under volta...
Страница 39: ...When L3 0 the controller will activate Non Hall model only when the Hall sensor in the motor fails When L3 1 the controller will choose the proper model to use according to the controller system optim...
Страница 40: ...arameters include general project parameter P parameter and C parameter of all KT LCD10H meter produced by our company according to requirements and set the meter to be a data source according to the...
Страница 41: ...e Both C9 power on password and C11 meter attributes can t be copied Besides LCD10H meter can only copy parameter of the same meter model User Setting Note After entering the user setting environment...