OPERATION 

 

The following section provides you with information on how 
to use the EliteSuite™ keypad. 

 

 

 

When the text [USER CODE] is shown this 

indicates that you are required to enter your 
user code. The default Master Code to gain 

access to your system is                    . This 
code MUST be changed, see section 0 on 
page 7 on how to program user codes

 

Many of the features and options must be 
enabled by the installation company or 

property manager. If the feature is not 
programmed or an option is not enabled the 

system will generate a rejection tone. Refer 
to the system configuration tables in section 

0 on page 26. 

INDICATOR LIGHTS 

 

The EliteSuite™ LCD keypad features three status indicator 
lights showing the condition of the EliteSuite™ Security 

System. 

 

 

 

 

 

 

    Power 

Trouble 

Indicator 

 

 

 

 

Ready Indicator 

 

 

 

 

Armed / Alarm Indicator 

 

 

Figure 1 - Indicator Lights 

Содержание EliteSuite

Страница 1: ...EliteSuite LCD Keypad User Manual...

Страница 2: ...EliteSuite User Manual PUBLICATION INFORMATION 5152 R First Publication 7075 R Update to User Programming Options Selection...

Страница 3: ...USER CODES 8 MODIFYING USER OPTIONS 10 User Card Numbers 14 ARMING DISARMING 17 EXIT DELAY 17 DISARMING 17 REGULAR ARMING 18 STAY ARMING 18 FORCE ARMING 19 BYPASSING ZONES 20 ONE KEY ARMING 21 SPECIAL...

Страница 4: ...ommunication The elegant and user friendly EliteSuite Keypad maintains complete control of your residence providing easy to understand information All the actions performed in your security system wil...

Страница 5: ...7 on how to program user codes Many of the features and options must be enabled by the installation company or property manager If the feature is not programmed or an option is not enabled the system...

Страница 6: ...he system is in alarm and you need to enter your user code When ON the system is armed and you may enter your user code to disarm VISUAL DISPLAY The EliteSuite LCD keypad features a rich 32 Character...

Страница 7: ...stem the display will scroll between the default display and the following screen Viewing Alarm Memory 1 Press and hold the memory key for 2 seconds or press memory and enter your USER CODE 2 Use the...

Страница 8: ...grammed to generate an audible tone every 120 seconds The trouble tone is cancelled when the trouble condition is viewed or the condition is returned to normal To silence the keypad completely see sec...

Страница 9: ...the EliteSuite system is open and may have been damaged Contact the property manager or security installation company to arrange for your system to be serviced Timer Loss A complete power failure of...

Страница 10: ...r code for your system A master code can perform the arm or disarm functions and modify and delete any user code change user options and modify user card numbers Other users can be given a master code...

Страница 11: ...o program to enter the User Setup menu for the user number that is displayed You can now choose from the Modify Code Options or Add Card selections explained below To choose another menu option press...

Страница 12: ...ey The EliteSuite keypad will then prompt for confirmation of the user code Repeat the user code and press the enter key to confirm Deleting User Codes To delete a user code follow the same procedure...

Страница 13: ...ess press or use the up and down keys to scroll to the Options menu and press the enter key Modifying User Options Use the up and down keys to scroll through the available options Press the key to tur...

Страница 14: ...s to the User Setup menu Option 3 Single Badge Disarming For Card Reader Interface Equipped Systems Only 5 Enabled allows the selected user to disarm the EliteSuite system by presenting the card progr...

Страница 15: ...Card Reader Interface Equipped Systems Only 5 Enabled allows the selected user to regular arm the EliteSuite system by presenting the card programmed for that user at the Card Reader three times in q...

Страница 16: ...for 2 hours upon presenting their card 3 times in quick succession 6 Disabled prevents triple card presenting from latch opening the door Option 7 Triple Badge Latch 4 Hours For Card Reader Interface...

Страница 17: ...Latch Option enabled may present their card three times while the door is latched open to cancel the latching and immediately lock the door User Card Numbers This menu is only for Card Reader interfa...

Страница 18: ...tails can now be entered manually via the keypad or automatically by presenting the card at a reader interface Manually Programming a User Card Using the keys enter the new Facility Number for the use...

Страница 19: ...eleting a User Card To delete a user Card Number follow the same procedure to program the Facility and Card Number and when the old number is displayed press the force key to clear the Facility or Car...

Страница 20: ...conds remains DISARMING To disarm an armed system or an alarm enter your user code An entry point like the front door will be programmed with an entry delay time When an entry point is opened the keyp...

Страница 21: ...be enabled by your property manager or installation company See the configuration section on page 26 STAY ARMING This method allows you to remain in the protected area while partially arming the syst...

Страница 22: ...o exit delay and arm in either force or regular arming FORCE ARMING Force Arming allows you to rapidly arm the system without waiting for all zones in the system to close During force arming a forced...

Страница 23: ...e system is disarmed the bypass settings are erased Bypassing Zones 1 Press the bypass key then enter your USER CODE 2 Use the up and down keys to scroll to the zone s you want to bypass 3 Press the b...

Страница 24: ...Press the enter key to store the bypass settings and exit 4 Press the clear key to exit without making changes ONE KEY ARMING One key arming can be used to arm the system in regular force stay and ins...

Страница 25: ...You can now use the up and down keys to scroll the zone s in the system Press the enter key to toggle the chime option for the selected zone You can now select another Chime Zone to edit by following...

Страница 26: ...GES The EliteSuite system provides powerful message handling capabilities to allow communication with a property or facility manager Up to four messages can be stored by the EliteSuite system A new me...

Страница 27: ...alarms can generate audible alarms sirens or bells or silent alarms and can communicate specific messages to your monitoring station or property manager Press hold keys and for the panic alarm Press...

Страница 28: ...manager or security company immediately to avoid an unnecessary response A delayed fire zone will automatically cancel if the smoke detector is reset within 30 seconds Pressing any key on the keypad...

Страница 29: ...names and any information about your system ZONE DESCRIPTION The following lists the zones in your system and how each zone is configured ZONE ZONE NAME FORCE STAY BYPASS 01 ZONE 1 5 5 5 02 ZONE 2 5 5...

Страница 30: ...s that are enabled on your system Enabled Disabled 1 3 Panic Alarm 5 4 6 Medical Alarm 5 7 9 Fire Alarm 5 TIMERS Your entry time is programmed to be _030_ seconds This is the time that you have before...

Страница 31: ...ble should be used to keep a record of the users programmed in your EliteSuite system Record the name of the user only Do not write the user code All users can arm and disarm the system USER USER NAME...

Страница 32: ...used in conjunction with products not manufactured by Seller Seller cannot guarantee the performance of the security system Seller s obligation and liability under this warranty is expressly limited...

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ...Unit C 6 Ascension Place Mairangi Bay P O Box 302 340 North Harbour Auckland New Zealand Phone 64 9 476 7124 y Fax 64 9 476 7128 www integratedcontroltechnology com...