background image

Содержание EliteSuite ELT-KLCS

Страница 1: ...ELT KLCS EliteSuite Touch Sense LCD Keypad User Manual ...

Страница 2: ...uced photocopied or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Integrated Control Technology Limited Designed and manufactured by Integrated Control Technology Limited Protege and the Protege Logo are registered trademarks of Integrated Control Technology Limited All other brand or product names are trademarks or regis...

Страница 3: ...Arming Disarming _____________________________________________________________ 14 Exit Delay ___________________________________________________________________________ 14 Disarming ___________________________________________________________________________ 14 Regular Arming ______________________________________________________________________ 14 Stay Arming ______________________________________...

Страница 4: ...____ 19 Timers ______________________________________________________________________________ 20 Users _______________________________________________________________________________ 20 Regulatory Statements_________________________________________________________ 21 Contact ______________________________________________________________________ 22 ...

Страница 5: ... functionality of condominium and apartment security with flexible local monitoring and offsite communication The elegant and user friendly EliteSuite keypad maintains complete control of your residence providing easy to understand information All actions performed in your security system are executed and displayed through the keypad Before using your EliteSuite system we highly recommend you read...

Страница 6: ...Visual Display The EliteSuite LCD keypad features a rich 32 character LCD Liquid Crystal Display showing customized messages All messages are shown on the LCD screen Indicator Lights Power Trouble Indicator Armed Alarm Indicator Disarmed Indicator Power Trouble Indicator When the Power Trouble Indicator is FLASHING it is showing that a trouble condition is present When ON the system is powered and...

Страница 7: ...hold the MEMORY key for 2 seconds or press MEMORY and enter your USER CODE 2 Use the UP and DOWN keys to scroll the alarm memory message 3 To choose another menu option press MENU or to exit press the CLEAR key The alarm memory can also be accessed from the main menu by pressing 3 or scrolling to the Memory option and pressing the ENTER key Clearing Alarm Memory The alarm memory is cleared automat...

Страница 8: ...y if the problem persists Zone Fault A zone in the system is faulty or the wiring has been damaged Contact the property manager or security installation company to arrange for your system to be serviced Cover Tamper The cover of the EliteSuite system is open and may have been damaged Contact the property manager or security installation company to arrange for your system to be serviced Timer Loss ...

Страница 9: ...ster code for your system A user with the master code can perform the arm or disarm functions modify and delete any user code change user options and modify user card numbers Other users may be given a master code by enabling User Option 2 for each new master user Refer to Modifying User Options see page 11 for further details Duress Code If you are forced to arm or disarm your system entering the...

Страница 10: ...ite system uses four digit user codes where each digit can be any value from 0 to 9 Avoid programming simple or obvious user codes such as part of your telephone number or address and codes such as 1234 1111 or 1212 Programming User Codes 1 From the User Setup Menu press 1 or use the UP and DOWN keys to scroll to the Modify Code option and press the ENTER key Select PIN 2 Using the 1 9 keys enter ...

Страница 11: ...s N Enabled allows the selected user to access the User Setup menu and modify codes card numbers and options of all other users Disabled prevents access to the User Setup menu Option 3 Single Badge Disarming For Card Reader Interface Equipped Systems Only Disarm On Single Badge Enabled N Enabled allows the selected user to disarm the system by presenting the card programmed for that user at the Ca...

Страница 12: ...iple card presenting from latch opening the door Option 7 Triple Badge Latch 4 Hours For Card Reader Interface Equipped Systems Only 3 Badge Latch Door 4 Hours N Enabled allows the selected user to hold a door open for 4 hours upon presenting their card 3 times in quick succession Disabled prevents triple card presenting from latching the door open Option 8 Triple Badge Latch 8 Hours For Card Read...

Страница 13: ...ypad or automatically by presenting the card at a reader interface Manually Programming a User Card Facility Number 0000000000 Using the 1 9 keys enter the new Facility Number for the user and then press the ENTER key The keypad will then prompt for the Card Number Card Number 0000000000 Automatically Programming a User Card Facility Number 0000000000 When at the Facility Number entry screen prese...

Страница 14: ...ed the keypad will emit a continuous audible tone until you disarm the system The system will not generate an alarm until this timer elapses All user codes can be used to disarm the system Deactivating Alarm To deactivate an alarm enter your USER CODE This will also disarm the system if it was armed Disarming Your System 1 If you enter through a designated entry point Entry Door the entry delay ti...

Страница 15: ... ARM key to switch to exit delay and arm in either force or regular arming Force Arming Force Arming allows you to rapidly arm the system without waiting for all zones in the system to close During force arming a forced zone is considered deactivated until it closes then the system will arm that zone Force arming is commonly used when a motion detector is protecting the area occupied by a keypad F...

Страница 16: ...es the previous bypass entries saved in memory This eliminates the need to manually re program the bypass entries every time you arm the system if you are always bypassing the same zone s 1 Press the BYPASS key then enter your USER CODE 2 Press and hold the BYPASS key for two seconds the last settings will be loaded You may change these settings if required 3 Press the ENTER key to store the bypas...

Страница 17: ...ntinue to generate a tone when a key is pressed and to provide audible confirmation 1 Press and hold the CLEAR key 2 The keypad will generate one long audible rejection tone to signify that the audible output is disabled To enable the audible output again repeat the steps above The keypad will generate four audible tones to indicate that the audible output has been enabled Messages The EliteSuite ...

Страница 18: ...Alarm activations must be enabled by your property manager or installation company Fire Alarm When a fire alarm occurs the keypad will emit three audible tones at two second intervals until reset by entering a valid user code If the zone is a delay fire zone there is a delay of 30 seconds before the system contacts the security company or property manager A delayed fire zone will prevent unnecessa...

Страница 19: ...ONE NAME FORCE STAY BYPASS 01 ZONE 1 02 ZONE 2 03 04 Fire Zone The following lists the fire zone configuration for your system Enabled Disabled Fire Zone Delayed Fire Zone Your fire zone is located on zone _________________________ and operates with a delay of _________ seconds One Key Arming The following lists the one key arming method s that are enabled on your system Enabled Disabled Regular A...

Страница 20: ... is programmed to be 30 seconds This is the time that you have to exit before the system arms If an alarm occurs the siren beeper will activate for 05 minutes unless disarmed Users The following table should be used to keep a record of the users programmed in your system Record the name of the user only Do not write the user code All users can arm and disarm the system USER USER NAME DURESS ARM ON...

Страница 21: ...3 A RCM Australian Communications and Media Authority ACMA This equipment carries the RCM label and complies with EMC and radio communications regulations of the Australian Communications and Media Authority ACMA governing the Australian and New Zealand AS NZS communities CE Compliance with European Union EU Conforms to European Union EU Low Voltage Directive LVD 2014 35 EC Electro Magnetic Compat...

Страница 22: ...ation below Integrated Control Technology P O Box 302 340 North Harbour Post Centre Auckland New Zealand 4 John Glenn Ave Rosedale North Shore City 0632 Auckland New Zealand Phone 64 9 476 7124 Toll Free Numbers 0800 ICT 111 0800 428 111 New Zealand 1800 ICT 111 1800 428 111 Australia 1855 ICT 9111 1855 428 9111 USA Canada Email sales incontrol co nz or support incontrol co nz Web www ict co ...

Страница 23: ......

Страница 24: ...4 590494 Designers manufacturers of integrated electronic access control security and automation products Designed manufactured by Integrated Control Technology Ltd Copyright Integrated Control Technology Limited 2003 2017 All rights reserved Disclaimer Whilst every effort has been made to ensure accuracy in the representation of these products neither Integrated Control Technology Ltd nor its emp...

Отзывы: