3.5 Unique EF-NODE Commands
Commands for measuring RF Intensity and the device’s battery level.
3.5.1 Send Fence Strength Command – fence strength
Command Input:
fence strength
Compatible:
All Device Firmware Versions
Command Description:
Provides current RF intensity value which is used as an indication of fence pulsing
strength. Use to establish in-situ RF intensity that correspond to electric fence status; e.g. operational, tripped
or unpowered states. This command should be used at installation to establish RF intensity values to indicate
these states in the payload decoder.
3.5.2 Send Battery Test – battery test
Command Input:
battery test
Compatible:
All Device Firmware Versions
Command Description:
Provides current battery voltage in millivolts. The example 5225 would equate with
5.22 Volts. Device operates to a lower voltage limit of 4.2volts.
3.5.3 Fence Low Alarm – fence threshold
Command Input:
fence threshold
Compatible:
All Device Firmware Versions
Command Description:
RF Intensity threshold, when value drops below the set value the node triggers a
confirmed message to the network server.
Type
Syntax Used
Response Type Example Result of Command
Get
fence strength
<value>
STRENGTH=2780
Type
Syntax Used
Response Type Example Result of Command
Get
battery test
<voltage>
BAT_MV=5225
Command
Type
Syntax Used
Example Command
Response
Type
Example Result of Command
Set
fence threshold
fence threshold
1000
<string>
1000
ICT INTERNATIONAL
Enabling better global research outcomes in soil, plant & environmental monitoring
19
Содержание EF-NODE
Страница 1: ...EF NODE Electric Fence Node Manual...