11
WIKA operating instructions submersible pressure transmitter, model LH-10
14075011.03 07/2016 EN/DE/FR/ES
EN
6. Commissioning, operation
WARNING!
Observe the working conditions in accordance with chapter 3 “Specifications”.
CAUTION!
Prior to commissioning, the submersible pressure transmitter must be subjected to a visual inspection.
■
Leaking fluid is indicative of damage.
■
Only use the submersible pressure transmitter if it is in perfect condition with respect to safety.
6.1 Mechanical mounting
The protection cap protects the internal diaphragm from damage. Remove the protective cap if the medium is viscous
or contaminated.
6. Commissioning, operation
Requirements for mounting point
The existence of strong electromagnetic fields in a frequency range of < 100 MHz may result in increased measuring
errors up to 0.5 %. Do not install the instruments in the vicinity of strong electromagnetic sources of interference (e.g.
transmitting devices, radio equipment), or use sheath current filters where applicable.
Protection cap
Internal diaphragm
Содержание LH-10
Страница 59: ...59 ES 14075011 02 12 2015 EN DE FR ES...
Страница 60: ......