Output
Sensor supply
24 VDC / 50 mA; 12 VDC / 50 mA; 5 VDC / 20 mA
Analog output
0/4-20 mA / burden 350
Ω
or 0-10 VDC / 10 kOhm, 16 bit
Switching output
Relay with change-over
contact
Switching cycles
250 VAC / 5 AAC; 30 VDC / 5 ADC
30 x 10
3
at 5 AAC, 5 ADC ohm resistive burden
10 x 10
6
mechanically
Division according to DIN EN50178 /
Characteristics accrording to DIN EN60255
Interface
Protocol
Modbus with ASCII or RTU-protocol
RS232
9.600 Baud, no parity, 8 Databit, 1 Stopbit,
wire length max. 3 m
RS485
9.600 Baud, no parity, 8 Databit, 1 Stopbit,
wire length max. 1000 m
Power supply
100-240 VAC 50/60 Hz, DC ± 10%, max. 15 VA
10-40 VDC; 18-30 VAC 50/60 Hz, max. 15 VA
Memory
EEPROM
Data life
≥
100 years at 25°C
Ambient conditions
Working temperature
0°…50°C for panel meters, -20°…60°C for built-on devices
Storing temperature
-20…80°C
Weathering resistance
relative humidity 0-80% on years average without dew
Height
up to 2000 m above sea level
EMV
EN 61326
CE-sign
Conformity according to directive 2004/108/EG
Safety standard
Accroding to low voltage directive 2006/95/EG
EN 61010; EN 60664-1
38
10. Technical data