8
5. Setting up the device
Menu level
Parameterisation level
Selection of the input signal,
tYPE
:
Default:
fre9u
If the scaling of the device is done via
SEnS.F
(Sensor calibration), the frequency range needs to
be preset under
rAnGE
and is adjusted by application of the final value / initial value. If
FrEqU
(factory calibration) is preferred, the final value needs to be entered under
End
and the final
frequency needs to be entered under
EndA
. Under
OFFS
the initial value needs to be entered and
under
OFFSA
the initial frequency. There is no application of the measuring signal. Confirm the
selection with
[P]
and the display switches back to menu level.
Setting the end value of the measuring range,
END
:
Default:
100e3
Choose between six different frequency ranges. Confirm the selection with
[P]
and the display
switches back to menu level.
Setting the final value of the measuring range,
END
:
Default:
10000
Set the final value from the smallest to the highest digit with
[
▲
] [
▼
]
and confirm each digit with
[P]
. A minus sign can only be parameterized on the highest value digit. After the last digit, the
display switches back to the menu level. If
Sens
was selected as input option, you can only
select between
noca
and
cal.
With
noca
, only the previously set display value is taken over, and
with
cal
, the device takes over both the display value and the analogue input value.
5. Setting up the device
9.9999 Hz
99.999 Hz
999.99 Hz
9.9999 kHz
99.999 kHz
999.99 kHz
5.1. Switching-on
Once the installation is complete, start the device by applying the voltage supply. Before, check
once again that all electrical connections are correct.
Starting sequence
For 1 second during the switching-on process, the segment test (
8 8 8 8 8
) is displayed, followed by
an indication of the software type and, after that, also for 1 second, the software version. After the
starting sequence, the device switches to operation/display mode.
5.2. Standard parameterisation:
(flat operation level)
To parameterize the display, press the
[P]
-key in operating mode for 1 second. The display then
changes to the menu level with the first menu item
TYPE
.