background image

Dimensional drawing series 

I

LW

Dimensional drawing series 

I

LK

83

57

83

41,5

12

40

220

1

15

40

18

26

57

1

15

83

83

50

12

Ordering Example

L

K

K

M

0V

F1

 48

05

00G

Series: 

I

L Series

Design: 

Duct version

Physical outputs: 

active outputs

Output signals: 

MODBUS RTU

 

Operation conditions / special versions:

Sealing against vibrations

Measured variable and output range 1:

Measured variable and output range 2:

Supply voltage:

5...30 V DC

Measuring head / Filter / Diameter:

PTFE sintered filter ZE05 / 12 mm

Description of design

Duct version, sensor tube length = 220 mm

Содержание IL Series

Страница 1: ...ree of protection housing IP65 Material of housing PC light grey white General data Power supply external 6 30 VDC Max transfer distance RS232 RS485 15m 1000 m Consumption of electronics 1 0 mA Direct...

Страница 2: ...d to check the accuracy of the sensors 84 rh at 25 C humidity standard to check the accuracy of the sensors 97 rh at 25 C ZE33 as designation F5 2 adapter for humidity standard ZE 31 1 Flange 20 045 f...

Страница 3: ...ature C enthalpy kJ kg mixing ratio g kg absolute humidity g m and wet bulb temperature C K 4 Output signals RS232 ASCII protocol R RS485 MODBUS RTU protocol M 5 6 Operation conditions special version...

Страница 4: ...Series Design Duct version Physical outputs active outputs Output signals MODBUS RTU Operation conditions special versions Sealing against vibrations Measured variable and output range 1 Measured vari...

Страница 5: ...dity occur The sensor tube resp measuring head or measuring chamber should be exposed to the flow of air Avoid installation next to heaters doors or on outer walls Avoid places exposed to the sun Not...

Страница 6: ...FLOAT32 Dew point temperature C 11 12 FLOAT32 Enthalpy kJ kg 13 14 FLOAT32 Mixing ratio g kg 15 16 FLOAT32 Absolute humidity g m 17 18 FLOAT32 Wet bulb temperature C 19 20 UINT16 Alarm code hx proces...

Страница 7: ...sor The Modbus address can be modified at any time via write access to the address register reg no 205 Permissi ble slave addresses are within the 1 247 range Using address 0 as a slave address is not...

Страница 8: ...rs in this impedance category 256 bus nodes are theoretically possible instead of 32 However due to the available address space in practice the number reduces to 247 The scanning interval should not e...

Страница 9: ...ret the decimal result as a hexadecimal number 56 38hex 5 Compare the individual hexadecimal numbers with the transmitted ASCII characters of the checksum 38hex 3 8 VisualPMU Freeware for RS232 This s...

Отзывы: